D.C. Generators - Armature Reaction

1 Answer

In a direct current (DC) generator, also known as a dynamo, electrical energy is converted from mechanical energy through electromagnetic induction. The generator consists of several components, one of which is the armature. The armature is the rotating part of the generator where the voltage is induced due to the relative motion between the magnetic field and the armature conductors.

Armature Reaction refers to the phenomenon that occurs in a DC generator when the magnetic field produced by the armature current interacts with the main magnetic field of the machine. This interaction can lead to certain effects on the generated voltage and the distribution of current within the machine.

When current flows through the armature conductors, it creates its own magnetic field around those conductors. This magnetic field interacts with the main magnetic field produced by the field windings, leading to the following effects:

Cross-Magnetizing Effect: This effect occurs when the armature current produces a magnetic field that is perpendicular to the main magnetic field. This can lead to distortion of the main field lines, causing an uneven distribution of flux density in the air gap. As a result, the generated voltage may not be constant across all segments of the armature windings.

Demagnetizing Effect: This effect occurs when the armature current creates a magnetic field that opposes the main magnetic field. This can weaken the overall magnetic field strength, leading to a reduction in the generated voltage.

To mitigate these effects, generators are often designed with certain measures:

Compensating Windings: Some generators are equipped with compensating windings that produce a magnetic field that opposes the armature reaction's demagnetizing effect. These windings help maintain a more stable main magnetic field.

Interpoles or Commutating Poles: In larger generators, interpoles or commutating poles are used. These are small poles placed between the main poles. Their magnetic field counters the effects of armature reaction, leading to improved commutation (the process of transferring current from the armature conductors to the external circuit).

Brush Shift: In some cases, the position of the brushes that make contact with the commutator is shifted slightly. This adjustment helps in compensating for the voltage drop caused by armature reaction.

In summary, armature reaction in DC generators is an important consideration in design and operation. It can affect the performance, voltage regulation, and efficiency of the generator. Various techniques are employed to mitigate its adverse effects and ensure stable and efficient generator operation.
0 like 0 dislike

Related questions

D.C. Generators - Remedies for Neutralising Armature Reaction
Answer : In direct current (DC) generators, armature reaction refers to the effect of the armature current on the magnetic field produced by the field windings. This interaction can lead ... combinations of these remedies to effectively neutralize armature reaction and ensure smooth and efficient operation....

Show More

D.C. Generators - types of d.c generator
Answer : DC generators, also known as dynamo or dynamos, are electrical machines that convert mechanical energy into direct current (DC) electrical energy. They operate based on the principle ... different applications based on factors like voltage regulation, load characteristics, and control requirements....

Show More

D.C. Generators - Shunt Generator Characteristics
Answer : Direct current (DC) generators are electrical devices that convert mechanical energy into electrical energy through electromagnetic induction. A shunt generator is a type of DC generator where the ... compound generators (series-parallel wound) or separately excited generators, may be more suitable....

Show More

D.C. Generators - Series Generator Characteristics
Answer : A DC series generator is a type of direct current (DC) generator in which the field winding and armature winding are connected in series, meaning that the current flows through ... series generators suitable for specific applications where their strengths align with the requirements of the system....

Show More

D.C. Generators - Separately-excited Generator
Answer : A separately-excited DC generator is a type of direct current (DC) generator in which the field winding (the field coil) is supplied with a separate, independent external voltage ... adoption of more efficient and versatile alternating current (AC) generators and power electronic devices....

Show More

D.C. Generators - Self-excited Generator
Answer : A self-excited generator is a type of direct current (DC) generator that can produce its own field current without requiring an external source of power for excitation. In other words ... design and control to ensure stable operation and voltage regulation, especially under varying load conditions....

Show More

D.C. Generators - Requirements and Paralleing of D.C. generators
Answer : Direct current (DC) generators are devices that convert mechanical energy into electrical energy in the form of direct current. They are commonly used in various applications such as power ... lead to instability, load imbalances, and potential damage to the generators and connected equipment....

Show More

D.C. Generators - Reluctance or Alignment Torque
Answer : D.C. generators, also known as direct current generators or dynamos, are devices that convert mechanical energy into electrical energy using the principles of electromagnetic induction. ... aim to minimize reluctance torque while maximizing alignment torque to achieve optimal generator performance....

Show More

D.C. Generators - Reasons for paralleling D.C. generators
Answer : Paralleling DC generators refers to the process of connecting multiple DC generators in parallel to supply a common load. This practice is commonly employed in various applications to ... systems and synchronization methods are employed to manage the paralleling process safely and efficiently....

Show More

D.C. Generators - principle of a generator
Answer : A DC generator, also known as a direct current generator or dynamo, is a device that converts mechanical energy into electrical energy in the form of direct current ( ... applications and educational settings to understand the principles of electromagnetic induction and electrical generation....

Show More

D.C. Generators - Power Stages
Answer : Direct Current (DC) generators, also known as dynamo or dynamos, are electromechanical devices that convert mechanical energy into electrical energy in the form of direct current. They ... Proper field excitation is also necessary to maintain the required magnetic field for efficient generation....

Show More

D.C. Generators - Power Stages
Answer : Direct Current (DC) generators, also known as dynamos or generators, are electrical devices that convert mechanical energy into direct current electricity. They operate based on the principle ... by more efficient and versatile alternating current (AC) generators and power distribution systems....

Show More

D.C. Generators - parts of a D.C. machine
Answer : Direct current (D.C.) generators, also known as D.C. machines, are electromechanical devices that convert mechanical energy into electrical energy in the form of direct current. ... types of winding arrangements and commutation systems, to suit specific applications and performance requirements....

Show More

D.C. Generators - Open-Circuit Characteristics (O.C.C.)
Answer : Direct current (D.C.) generators are electromechanical devices that convert mechanical energy into electrical energy through the process of electromagnetic induction. The open-circuit characteristic (O.C.C. ... types of generators, such as alternators used for generating alternating current (A.C.)....

Show More

D.C. Generators - Losses in DC Generator
Answer : DC generators, also known as dynamos or direct current generators, are electrical machines that convert mechanical energy into direct current (DC) electrical power. Like any other ... and compound generators, may have varying loss characteristics based on their configurations and applications....

Show More

D.C. Generators - Induced voltage
Answer : Direct Current (DC) generators are electromechanical devices that convert mechanical energy into electrical energy in the form of direct current. They operate based on the principle of electromagnetic ... the generation of voltage, which in turn produces direct current in an external circuit....

Show More

D.C. Generators - Electromagnetic Torque
Answer : A DC generator, also known as a dynamo or a direct current generator, is a device that converts mechanical energy into electrical energy using electromagnetic principles. One of the key ... -carrying armature conductors, and it results in the conversion of mechanical energy into electrical energy....

Show More

D.C. Generators - Efficiency
Answer : The efficiency of a direct current (DC) generator refers to how effectively it converts mechanical power into electrical power. It is a measure of how well the generator ... is crucial for determining its economic feasibility and its compatibility with specific power generation requirements....

Show More

D.C. Generators - E.M.F. Equation
Answer : A DC (Direct Current) generator, also known as a dynamo or a DC machine, is a device that converts mechanical energy into electrical energy in the form of a direct current. The ... factors can lead to differences between the theoretical EMF and the actual output voltage of the generator....

Show More

D.C. Generators - DC Generator
Answer : A DC generator, also known as a direct current generator or dynamo, is an electrical machine that converts mechanical energy into direct current (DC) electrical energy. It is a device that ... battery charging, traction systems, and some industrial processes where a constant DC supply is required....

Show More

D.C. Generators - Condition for Maximum Efficiency
Answer : Direct current (DC) generators, also known as dynamo or dynamos, are devices that convert mechanical energy into electrical energy in the form of direct current. The efficiency of ... characteristics, and generator specifications all play a role in determining the optimal conditions for efficiency....

Show More

D.C. Generators - Compound Wound Generators Characteristics
Answer : Compound-wound DC generators are a type of direct current (DC) generator used to convert mechanical energy into electrical energy. These generators have both series and shunt field windings, ... them suitable for a range of applications where consistent and reliable power supply is essential....

Show More

D.C. Generators - Commutation and its types
Answer : Direct current (DC) generators are devices that convert mechanical energy into electrical energy, producing a continuous flow of electric current in one direction. Commutation is a crucial aspect of DC ... a more stable commutation process. The goal of commutation is to ensure that the current...

Show More

D.C. Generators - Characteristics of DC Generators
Answer : Direct Current (DC) generators are electrical devices that convert mechanical energy into direct current electricity. They are commonly used in various applications, including power generation, ... still find applications in specific industries and settings where direct current is required....

Show More

D.C. Generators - brush drop
Answer : In the context of direct current (DC) generators, "brush drop" refers to the voltage drop that occurs across the brushes and brush contacts in a DC generator. Brushes are used to ... DC generators, its impact can be minimized through proper maintenance practices and using high-quality components....

Show More

D.C. Generators - Applications of Shunt Generators
Answer : Shunt generators are a type of direct current (DC) generator that have their field windings connected in parallel (shunt) with the armature windings. They are widely used for ... generators still find their niche in specific applications where their characteristics and simplicity are advantageous....

Show More

D.C. Generators - Applications of Series Generators
Answer : Series DC generators have several applications due to their unique characteristics. These generators produce a current that is directly proportional to the load, making them suitable for certain ... or compound generators, are often preferred due to their improved voltage regulation and versatility....

Show More

D.C. Generators - Applications of Separately Excited Generators
Answer : Rotor eccentricity in induction motor drives refers to the condition where the center of the rotor (the rotating part of the motor) is not aligned with the center of the stator (the ... , repairing or replacing the motor may be necessary to restore optimal performance and prevent further damage....

Show More

D.C. Generators - Applications of Compound Generators
Answer : Compound DC generators find applications in various industrial and commercial settings where a combination of characteristics such as good voltage regulation, load handling capability, and simplicity ... handling capabilities, making them suitable for a range of industrial and commercial purposes....

Show More

D.C. Generators - Advantages and Disadvantages of Carbon Brushes
Answer : Carbon brushes play a crucial role in the operation of D.C. generators by providing electrical contact between the rotating armature and the stationary parts of the generator. They ... sparking and debris generation should be taken into consideration when using them in generator applications....

Show More

D.C. Motors - Mechanical power developed by motor armature
Answer : Mechanical power developed by a DC motor's armature is the output power generated by the motor's rotating component, known as the armature. This mechanical power is a result of converting electrical ... to perform mechanical work, and it is influenced by factors such as torque and angular velocity....

Show More

D.C. Motors - Armature Torque of a Motor
Answer : Armature torque is a crucial concept in the realm of DC motors and plays a significant role in their operation. A DC motor consists of several components, including the armature (rotating ... field. This torque is a crucial parameter in determining the motor's performance in various applications....

Show More

D.C. Motors - Armature Resistance Control
Answer : DC motors are widely used in various applications due to their simplicity, reliability, and controllability. One of the methods used to control the speed and performance of DC motors is by manipulating the ... need a simple and cost-effective way to control a DC motor's speed and torque output....

Show More

Measurement and Instrumentation - Modern D.C. Potentiometers
Answer : Modern direct current (D.C.) potentiometers are precision instruments used for accurate measurement of voltage, current, resistance, and other electrical quantities. They operate based on ... remain valuable tools for precise measurement and calibration applications where high accuracy is paramount....

Show More

Measurement and Instrumentation - D.C. Potentiometer
Answer : A Direct Current (D.C.) potentiometer is a precision instrument used for measuring voltage, electromotive force (EMF), and potential difference. It works on the principle of the potentiometer ... voltages with great precision by directly comparing the unknown voltage with a known standard voltage....

Show More

Measurement and Instrumentation - Crompton D.C. Potentiometer
Answer : The Crompton DC Potentiometer is a type of measurement instrument used for accurate measurement of voltage and current in electrical circuits. It's commonly used in laboratories, industries, and ... operation. There might be variations in design and usage based on specific models and applications....

Show More

Measurement and Instrumentation - Applications of D.C. Potentiometers
Answer : Direct Current (D.C.) potentiometers are versatile instruments used for various measurement and calibration purposes. They rely on the principle of comparing unknown voltages with a ... as in various scientific and industrial applications where precise measurements and calibrations are essential....

Show More

A.C. Fundamentals - Laplace transform of derivative [d f(t)/dt]
Answer : The Laplace transform is a mathematical technique used to analyze and solve linear time-invariant systems in the domain of complex numbers. It is particularly useful in solving ... differential equations, but it requires understanding the properties and manipulation techniques associated with it....

Show More

Single Phase Induction Motors - torque characteristics of a universal motor both for D.C. and A.C. supply
Answer : A universal motor is a type of electric motor that is designed to operate on both alternating current (AC) and direct current (DC) power sources. It is commonly used in applications where ... specific design of the universal motor, the quality of the materials used, and the operating conditions....

Show More

Network Theorems And Circuit Theory - Thevenin's Theorem with d.c
Answer : Thevenin's Theorem is a fundamental concept in circuit theory that simplifies complex linear circuits into simpler equivalents. It helps analyze and solve electrical circuits more efficiently by reducing ... to simplify analysis but doesn't provide deeper insights into the circuit's workings....

Show More

Network Theorems And Circuit Theory - Tellegen's Theorem with d.c
Answer : Tellegen's theorem is a fundamental principle in electrical circuit theory that relates the power flows within a network or circuit. It states that for any linear, bilateral electrical network, the ... a direct solving method but rather as a way to validate the results of circuit analysis....

Show More

Network Theorems And Circuit Theory - Superposition Theorem with d.c
Answer : The Superposition Theorem is a fundamental concept in electrical circuit theory that simplifies the analysis of linear circuits with multiple sources. It states that the response (voltage or current) ... is primarily used for analysis purposes and not for solving real-world circuit design problems....

Show More

Network Theorems And Circuit Theory - Reciprocity Theorem with d.c
Answer : The Reciprocity Theorem is a fundamental concept in circuit theory that applies to linear, time-invariant electrical networks. It states that the ratio of a response (such as voltage ... measuring impedance parameters, and understanding the behavior of sensors or transducers in reciprocal networks....

Show More

Network Theorems And Circuit Theory - Norton's Theorem with d.c
Answer : Norton's Theorem is a fundamental concept in circuit theory that provides a way to simplify linear electronic circuits containing multiple voltage or current sources. It's named after Edward ... with a resistor. This theorem is extremely useful for circuit analysis, design, and troubleshooting....

Show More

Network Theorems And Circuit Theory - Millman's Theorem with d.c
Answer : Millman's theorem is a network theorem in circuit theory that allows you to simplify complex parallel resistor-voltage source networks into a single equivalent voltage source and a single equivalent ... alternating current (a.c.) circuits due to the consideration of impedance and phase differences....

Show More

Network Theorems And Circuit Theory - Maximum Power Transfer Theorem with d.c
Answer : The Maximum Power Transfer Theorem is a fundamental concept in circuit theory that deals with optimizing the power transfer from a source to a load in an electrical circuit. This theorem ... theorem applies to AC circuits as well, involving complex impedance calculations instead of just resistance....

Show More

Network Theorems And Circuit Theory - Compensation Theorem with d.c
Answer : The Compensation Theorem, also known as the Reciprocity Theorem, is a fundamental concept in electrical circuit theory. It's closely related to other network theorems like the Thevenin's Theorem and the Norton's ... you'd like to discuss, please provide more details, and I'd be happy to assist you!...

Show More

Electrostatics - Transients in D.C. Circuits
Answer : In the context of electrostatics and direct current (D.C.) circuits, transients refer to the temporary changes in voltage, current, or charge that occur when the circuit is ... managing these transients are crucial for designing reliable electronic circuits and preventing damage to components....

Show More

Electrostatics - Behaviour of Capacitor in a D.C. Circuit
Answer : In a direct current (D.C.) circuit, a capacitor behaves differently compared to its behavior in an alternating current (A.C.) circuit due to the nature of the applied voltage. Let's explore ... D.C. circuit is crucial for various applications, such as energy storage, filtering, and timing circuits....

Show More

D.C. Motors - Ward-Leonard System
Answer : The Ward-Leonard System, also known as the Ward-Leonard Control, is a method of controlling the speed of a DC (direct current) motor. It was developed by Harry Ward Leonard in ... the history of motor control and automation, providing a foundation for later developments in motor control technology....

Show More
...