🔍
D.C. Motors - Applications of Separately excited D.C. Motors

1 Answer

Separately excited DC motors are a type of direct current motor where the field winding (excitation winding) and the armature winding are supplied with separate and independent voltage sources. This design provides better control over the motor's speed and torque characteristics, making them suitable for a variety of applications. Here are some common applications of separately excited DC motors:

Industrial Machinery: Separately excited DC motors are used in various industrial machinery where precise speed control is essential, such as conveyor systems, printing presses, textile machinery, and paper mills.

Machine Tools: These motors are employed in machine tools like lathes, milling machines, and drilling machines, where accurate and adjustable speed control is necessary for different machining operations.

Rolling Mills: Separately excited DC motors are used in rolling mills to drive the rollers that shape and process metals into sheets, rods, and other forms. Their speed control is crucial for controlling the thickness and quality of the final product.

Elevators and Escalators: DC motors are commonly used in elevator and escalator systems due to their ability to provide smooth and precise speed control for vertical transportation.

Hoists and Cranes: DC motors are ideal for hoists and crane systems where precise lifting and lowering speeds are necessary for safe and efficient material handling.

Traction Applications: Separately excited DC motors have been used in some traction applications, such as electric trains, trams, and trolleys. Their speed and torque control capabilities make them suitable for these purposes.

Paper and Textile Industry: In the paper and textile industries, where maintaining consistent tension in materials is crucial, DC motors provide the necessary control for winding and unwinding processes.

Centrifuges: In laboratories and industrial settings, centrifuges use DC motors for spinning samples at controlled speeds to separate components based on density.

Robotics: In certain robotics applications, DC motors can be used for joint movement, especially when precise control of movement and positioning is required.

Automotive Industry: Though less common today, separately excited DC motors have been used in automotive applications like power windows, windshield wipers, and cooling fan systems due to their adjustable speed control features.

Battery-Powered Systems: DC motors are often used in battery-powered systems like electric wheelchairs, golf carts, and electric scooters due to their simplicity and efficient control mechanisms.

Test and Measurement Equipment: DC motors are used in equipment like dynamometers and test rigs to simulate various conditions and measure the performance of other machines or systems.

The versatility of separately excited DC motors lies in their ability to provide precise control over speed and torque, making them suitable for applications where variability and control are paramount. However, it's worth noting that in some cases, modern technology has shifted toward using more efficient and digitally controlled motor types, such as brushless DC motors and AC induction motors, due to advancements in control and energy efficiency.
0 like 0 dislike

Related questions

D.C. Motors - Characteristics of a Shunt or Separately-excited DC Motor
Answer : A shunt or separately-excited DC motor is a type of direct current (DC) motor where the field winding (excitation winding) and the armature winding are connected in parallel or "shunt." This ... other types of DC motors, such as series-wound or compound-wound motors, might be more appropriate....

Show More

D.C. Generators - Applications of Separately Excited Generators
Answer : Rotor eccentricity in induction motor drives refers to the condition where the center of the rotor (the rotating part of the motor) is not aligned with the center of the stator (the ... , repairing or replacing the motor may be necessary to restore optimal performance and prevent further damage....

Show More

D.C. Generators - Separately-excited Generator
Answer : A separately-excited DC generator is a type of direct current (DC) generator in which the field winding (the field coil) is supplied with a separate, independent external voltage ... adoption of more efficient and versatile alternating current (AC) generators and power electronic devices....

Show More

D.C. Motors - Applications of shunt D.C. Motors
Answer : Shunt DC motors are a type of direct current (DC) motor that has the field winding connected in parallel (shunt) with the armature winding. These motors are commonly used in various ... , but shunt DC motors continue to be utilized in industries where their specific characteristics are beneficial....

Show More

D.C. Motors - Applications of D.C. series Motors
Answer : DC series motors have a unique characteristic where the field windings are connected in series with the armature windings. This design gives them specific performance characteristics that make them ... motors, have become more prevalent due to their higher efficiency and improved control mechanisms....

Show More

D.C. Motors - Applications of compound D.C. Motors
Answer : Compound DC motors, also known as compound-wound DC motors, are a type of electric motor that combines elements of both series-wound and shunt-wound DC motors. They have both ... However, compound DC motors still find use in specific scenarios where their unique characteristics are advantageous....

Show More

D.C. Motors - Ward-Leonard System
Answer : The Ward-Leonard System, also known as the Ward-Leonard Control, is a method of controlling the speed of a DC (direct current) motor. It was developed by Harry Ward Leonard in ... the history of motor control and automation, providing a foundation for later developments in motor control technology....

Show More

D.C. Motors - Voltage Equation of a Motor
Answer : The voltage equation of a DC motor describes the relationship between the applied voltage, the motor's back electromotive force (EMF), the current flowing through the motor, and the motor's ... systems, such as adjusting the speed or torque of the motor by varying the applied voltage....

Show More

D.C. Motors - Voltage control
Answer : DC motors are widely used in various applications where controlled motion is required. Voltage control is one of the fundamental methods for controlling the speed and torque of DC ... , load characteristics, and the application requirements when selecting the appropriate voltage control method....

Show More

D.C. Motors - Usage of DC Motors
Answer : DC (Direct Current) motors are electric motors that convert electrical energy into mechanical energy through the interaction of magnetic fields. They are widely used in various applications ... , higher power densities, and reduced maintenance requirements compared to traditional brushed DC motors....

Show More

D.C. Motors - Uncontrolled Rectifiers
Answer : D.C. motors are often used in various industrial and commercial applications due to their efficiency, controllability, and reliability. Uncontrolled rectifiers are a type of power electronic ... for better control and performance, controlled rectifiers and advanced control techniques are preferred....

Show More

D.C. Motors - Types of Thyristor Drives
Answer : Thyristor drives, also known as thyristor-controlled drives or thyristor-controlled rectifier drives, are used to control the speed and direction of DC motors by regulating the voltage applied to the ... might have introduced new types or variations of thyristor drives beyond what's mentioned here....

Show More

D.C. Motors - Types of DC Motors
Answer : DC motors are electrical devices that convert direct current (DC) electrical energy into mechanical motion. There are several types of DC motors, each designed for specific applications based on ... specific requirements of the application, such as torque, speed, size, and control characteristics....

Show More

D.C. Motors - Torque-current characteristics
Answer : Direct current (DC) motors are widely used in various applications, ranging from industrial machinery to household appliances and automotive systems. One of the important characteristics of DC motors is their ... type of DC motor (brushed or brushless) and the motor's design and control strategies....

Show More

D.C. Motors - torque developed in a motor
Answer : A DC (direct current) motor is an electric motor that converts electrical energy into mechanical motion. One of the important characteristics of a DC motor is the torque it can develop. Torque is ... these factors, the torque output of a DC motor can be adjusted to suit various applications....

Show More

D.C. Motors - Thyristor Control of d.c motor
Answer : Thyristor control of DC motors involves using thyristor-based circuits to regulate the speed and direction of direct current (DC) motors. Thyristors are solid-state devices that can act as ... , and the benefits and limitations of thyristor-based control in comparison to other available methods....

Show More

D.C. Motors - Thyristor Choppers
Answer : D.C. motors are widely used in various industrial and commercial applications due to their controllable speed, torque, and reliability. However, controlling the speed of a ... implementation require careful consideration of control strategies, protection mechanisms, and potential harmonics issues....

Show More

D.C. Motors - Three-point starter
Answer : A three-point starter is a type of control device used in direct current (DC) motors to start, stop, and control their speed. It is commonly used for controlling shunt and ... three-point starters in many applications due to their improved efficiency, precise control, and automation capabilities....

Show More

D.C. Motors - testing of d.c machines
Answer : Testing DC motors involves various procedures to ensure their proper functioning, efficiency, and performance. These tests are essential to verify whether the motors meet design specifications and ... tests in accordance with relevant standards and guidelines to ensure accurate and reliable results....

Show More

D.C. Motors - Starters for Shunt and Compound Motors
Answer : Direct Current (D.C.) motors are widely used in various industrial and commercial applications. To start and control the speed of D.C. motors, starters are employed. Starters are devices that ... are crucial for the safe and efficient operation of D.C. motors in various industrial settings....

Show More

D.C. Motors - Speed-torque (or mechanical) characteristics
Answer : DC motors are widely used in various applications that require precise control of speed and torque. The speed-torque characteristics of a DC motor describe its behavior in terms of speed ... systems that use DC motors, ensuring they operate efficiently and reliably for their intended applications....

Show More

D.C. Motors - Speed-current characteristics
Answer : DC motors are widely used in various applications due to their controllable speed and torque characteristics. One important aspect of understanding a DC motor's behavior is its speed-current ... the right motor for their specific needs and optimize its performance for different operating conditions....

Show More

D.C. Motors - speed of d.c shunt motor by Field rheostatic control
Answer : In a DC shunt motor, the speed can be controlled using field rheostatic control by varying the field current. The field rheostat is a variable resistor connected in series ... control using microcontrollers and feedback mechanisms to achieve accurate speed control without significant energy losses....

Show More

D.C. Motors - speed of d.c series motor by Rheostatic control
Answer : A DC series motor is a type of direct current (DC) motor where the field winding is connected in series with the armature winding. These motors have the characteristic of high starting torque ... up until September 2021, and there may have been advancements or changes in technology since that time....

Show More

D.C. Motors - speed of a d.c motor
Answer : The speed of a DC motor, also known as its rotational speed or angular velocity, is determined by several factors, primarily the voltage applied to the motor's terminals and its mechanical ... other factors that can influence the motor's actual speed under a given set of operating conditions....

Show More

D.C. Motors - Speed Control of DC Motors
Answer : Speed control of DC motors is a crucial aspect of various industrial, commercial, and residential applications. DC motors are widely used because of their simplicity, reliability, and controllability ... the use of feedback systems helps maintain the desired speed even under varying load conditions....

Show More

D.C. Motors - Speed Control of D.C. Motor with Thyristor
Answer : Speed control of DC motors using thyristors is a commonly used technique in industrial applications. Thyristors are solid-state devices that can control the flow of current in a circuit, making ... controllers have become more popular due to their efficiency, flexibility, and better power quality....

Show More

D.C. Motors - Special Features of Thyristor Drive Motors
Answer : Thyristor drives, also known as silicon-controlled rectifier (SCR) drives, are a type of electric drive used to control the speed and torque of DC motors. These drives offer several special ... offer even greater efficiency, flexibility, and control capabilities for a wider range of motor types....

Show More

D.C. Motors - Shunt Motor
Answer : A DC shunt motor is a type of direct current (DC) motor that operates using the shunt field winding configuration. It falls under the broader category of DC motors, which convert ... applications, although specific motor selection should be based on the requirements of the application at hand....

Show More

D.C. Motors - Series-parallel control method
Answer : The series-parallel control method is a technique used to control the speed and torque characteristics of a DC motor by changing its armature (rotor) winding configuration. This method is ... DC motors, but it requires careful design and control to ensure optimal performance and reliability....

Show More

D.C. Motors - Rotational Losses of DC Machines
Answer : Rotational losses in DC motors, also known as mechanical losses, are the losses that occur due to the physical motion of the motor's components. These losses contribute to reducing the ... practically impossible due to the nature of energy conversions and the physical limitations of the components....

Show More

D.C. Motors - Relationship between Speed, Back E.M.F., and Flux
Answer : In a DC (direct current) motor, the relationship between speed, back electromotive force (EMF), and flux is described by the motor's fundamental operating principle, known as the motor equation. ... motor will affect the speed, back EMF, and flux, thus influencing its performance and efficiency....

Show More

D.C. Motors - principle of d.c motor
Answer : A DC motor, short for Direct Current motor, is an electrical machine that converts electrical energy into mechanical energy through the interaction of magnetic fields. The basic principle of ... simplicity, controllability, and ability to provide consistent torque over a wide range of speeds....

Show More

D.C. Motors - need of starter for d.c motors
Answer : In direct current (DC) motors, a starter is often used to control the starting current and provide a safe and controlled way to start the motor. Here are the main reasons why starters ... starter used depends on factors such as the motor's size, application, and desired starting characteristics....

Show More

D.C. Motors - Necessity of a Starter for Starting DC Motors
Answer : DC motors require a starter for various reasons, primarily to control the initial current surge and ensure proper starting conditions. Here's why a starter is necessary for starting DC motors: ... tear, control acceleration, and ensure proper operation of both the motor and the connected equipment....

Show More

D.C. Motors - Mechanical power developed by motor armature
Answer : Mechanical power developed by a DC motor's armature is the output power generated by the motor's rotating component, known as the armature. This mechanical power is a result of converting electrical ... to perform mechanical work, and it is influenced by factors such as torque and angular velocity....

Show More

D.C. Motors - Mechanical (or friction) losses.
Answer : DC motors are electromechanical devices that convert electrical energy into mechanical motion. While they are highly efficient in their operation, they do experience various losses, including ... . This contributes to improved efficiency and reliability compared to traditional brushed DC motors....

Show More

D.C. Motors - Losses
Answer : D.C. motors, like any other electrical machines, experience various types of losses during their operation. These losses contribute to reducing the overall efficiency of the motor and affect ... efficient cooling and ventilation systems to mitigate these losses and improve the motor's performance....

Show More

D.C. Motors - Iron losses
Answer : DC motors are devices that convert electrical energy into mechanical energy through the interaction of magnetic fields. They consist of various components, including a rotor (armature) and a ... play a significant role in designing efficient and reliable DC motor systems for various applications....

Show More

D.C. Motors - Four-point starter
Answer : A four-point starter is an electrical device used to control the speed and direction of a direct current (DC) motor. It is commonly employed in applications where precise control over the motor ... the motor's behavior is required, such as in industrial machinery, locomotives, and conveyor systems....

Show More

D.C. Motors - Field Resistance Control
Answer : Field resistance control is a method used to control the speed of a DC motor by changing the resistance of the field winding. In a DC motor, the field winding is ... are electronically controlled and provide better energy efficiency and control accuracy compared to field resistance control....

Show More

D.C. Motors - Field control method
Answer : DC motors can be controlled using various methods, and one of those methods is field control. Field control involves changing the strength of the magnetic field within the motor to control its ... and accurate control, better energy efficiency, and reduced wear and tear on the motor components....

Show More

D.C. Motors - Electric braking of shunt motors
Answer : Electric braking is a method of stopping or slowing down a DC motor by using its own generated electromotive force (EMF) to counteract the applied voltage. Shunt DC motors are one ... equipment. Proper control systems and circuitry are often used to manage the braking process effectively....

Show More

D.C. Motors - Electric braking of series motor
Answer : Electric braking is a method used to quickly stop or decelerate an electric motor by converting the motor's kinetic energy into electrical energy, which is then dissipated as heat. In the ... and ensure that the dissipation of generated energy is managed to avoid overheating or other issues....

Show More

D.C. Motors - Electric braking and its types
Answer : DC motors are widely used in various applications and can be controlled using different techniques, including electric braking. Electric braking is a method of slowing down or stopping a ... measures when using electric braking techniques to ensure the motor and associated equipment are protected....

Show More

D.C. Motors - Efficiency curve
Answer : The efficiency curve of a DC motor represents the motor's efficiency across its operating range, usually plotted as a graph with motor speed or load on the x-axis and efficiency ... 's datasheet or specifications will provide you with accurate efficiency information for that particular motor model....

Show More

D.C. Motors - efficiency
Answer : Efficiency in the context of DC motors refers to the ratio of useful output power to the input power required to run the motor. It is an important parameter in assessing the performance of a ... other factors such as torque, speed, size, and cost, depending on the requirements of the application....

Show More

D.C. Motors - Effects of Thryistor Power Supply on the D.C..Motor Performance
Answer : A thyristor is a solid-state semiconductor device that is often used in power control applications. When it comes to DC motors, thyristor-based power supplies can have several effects on ... issues like overvoltage or overcurrent conditions that could damage the motor or the power supply system....

Show More

D.C. Motors - Disadvantages of Ward-Leonard system
Answer : The Ward-Leonard system, also known as the Ward-Leonard control or Ward-Leonard drive, is a method of controlling the speed of a DC motor by using an adjustable DC voltage ... motor control methods offer greater efficiency, reliability, flexibility, and better control over motor performance....

Show More

D.C. Motors - DC Series Motor
Answer : A DC Series Motor is a type of direct current (DC) electric motor where the field winding and armature winding are connected in series. This means that the same current ... motors. These newer technologies often offer better performance, higher efficiency, and reduced maintenance requirements....

Show More
...