🔍
A.C. Fundamentals - Partial fraction expansion

1 Answer

Partial fraction expansion is a technique used in mathematics, specifically in calculus and algebra, to decompose a rational function into a sum of simpler fractions, called partial fractions. This technique is particularly useful when dealing with integrals of rational functions or solving linear differential equations.

The general form of a rational function is:


(

)
=

(

)

(

)
,
R(x)=
Q(x)
P(x)
    ​

,

where

(

)
P(x) and

(

)
Q(x) are polynomials, and the degree of

(

)
Q(x) is greater than the degree of

(

)
P(x).

Partial fraction expansion involves breaking down the rational function

(

)
R(x) into a sum of partial fractions in the form:


(

)

(

)
=

1
(



1
)
+

2
(



2
)
+

+


(




)
,
Q(x)
P(x)
    ​

=
(x−r
1
    ​

)
A
1
    ​

    ​

+
(x−r
2
    ​

)
A
2
    ​

    ​

+⋯+
(x−r
n
    ​

)
A
n
    ​

    ​

,

where

1
,

2
,

,


r
1
    ​

,r
2
    ​

,…,r
n
    ​

 are distinct roots of the polynomial

(

)
Q(x), and

1
,

2
,

,


A
1
    ​

,A
2
    ​

,…,A
n
    ​

 are constants that need to be determined.

The process of finding the constants

1
,

2
,

,


A
1
    ​

,A
2
    ​

,…,A
n
    ​

 involves various methods, depending on the nature of the roots of

(

)
Q(x) and the degree of the polynomial. The main approaches include:

Distinct Linear Factors: If

(

)
Q(x) has distinct linear factors, the partial fractions can be written as above, and the constants can be found by equating coefficients.

Repeated Linear Factors: If

(

)
Q(x) has repeated linear factors, the partial fractions involve terms like

1
(



1
)
+

2
(



1
)
2
+

(x−r
1
    ​

)
A
1
    ​

    ​

+
(x−r
1
    ​

)
2
A
2
    ​

    ​

+⋯, and the constants are determined similarly.

Irreducible Quadratic Factors: If

(

)
Q(x) has irreducible quadratic factors, the partial fractions will include terms like


+

(


2
+


+

)
(ax
2
+bx+c)
Ax+B
    ​

, and the constants are found by comparing coefficients of

x and the constant term.

Once the partial fractions are found, the original rational function can be expressed as a sum of these simpler fractions, which often makes integration or solving differential equations easier.

Partial fraction expansion is widely used in various areas of mathematics and engineering, including calculus, differential equations, signal processing, and control systems. It simplifies complex expressions and allows for easier manipulation and analysis of functions involving rational terms.
0 like 0 dislike

Related questions

A.C. Fundamentals - Heaviside Expansion Theorem
Answer : The Heaviside Expansion Theorem, also known as the Heaviside cover-up method, is a technique used in electrical engineering and circuit analysis to find the partial fraction expansion ... Laplace transforms, which are necessary to obtain time-domain solutions from frequency-domain representations....

Show More

A.C. Fundamentals - Z-parameters
Answer : In electrical engineering, A.C. (alternating current) fundamentals are an essential aspect of understanding how electrical circuits behave when exposed to varying voltages and currents. One way ... of components and networks becomes crucial due to the frequency-dependent behavior of these systems....

Show More

A.C. Fundamentals - Y-Parameter
Answer : Y-parameters, also known as admittance parameters or hybrid parameters, are a set of parameters used to describe the behavior of a linear two-port network. Y-parameters are particularly useful ... specific use and interpretation might vary based on the context and type of circuit being analyzed....

Show More

A.C. Fundamentals - Waveform
Answer : Alternating Current (AC) fundamentals are essential concepts in electrical engineering and physics that deal with the behavior of electric currents that periodically change direction. One ... helps engineers design and troubleshoot AC circuits, ensuring optimal performance and functionality....

Show More

A.C. Fundamentals - Voltages, Currents, and Power in Y Connection
Answer : In electrical engineering, AC (alternating current) fundamentals play a crucial role in understanding the behavior of AC circuits. One common configuration is the Y connection, also known ... essential for analyzing and designing AC circuits, especially in industrial and power distribution systems....

Show More

A.C. Fundamentals - Voltages, Currents, and Power in Delta Connection
Answer : In electrical engineering, the delta connection (also known as a "mesh" or "3-wire" connection) is one of the configurations used to connect three-phase voltage and current ... -world scenarios, power systems may have various complexities and considerations that could affect the calculations....

Show More

A.C. Fundamentals - Variation of Z and i with Frequency
Answer : In the context of electrical circuits and AC (alternating current) fundamentals, let's discuss the variation of impedance (Z) and current (i) with frequency. Impedance (Z): ... and analysis of AC circuits and is fundamental to various applications in electrical engineering and electronics....

Show More

A.C. Fundamentals - Variation of XL, Xc, R, and Z with Frequency
Answer : In the context of alternating current (AC) circuits, XL, XC, R, and Z are important parameters that describe the behavior of circuit elements in response to varying frequency. Let' ... , as well as for applications in fields such as electronics, electrical engineering, and telecommunications....

Show More

A.C. Fundamentals - Values of Alternating Voltage and Current
Answer : Alternating Current (AC) fundamentals involve understanding the properties and values of alternating voltage and current. AC is the type of electric current that changes direction periodically, as opposed ... as they form the basis for analyzing and designing various electrical systems and devices....

Show More

A.C. Fundamentals - Unit-Step Function
Answer : Certainly, I can help you with that! In the context of A.C. (Alternating Current) Fundamentals, the Unit Step Function is often referred to as the Heaviside step function, or simply the unit ... . If you have specific questions or scenarios in mind, feel free to ask for more detailed explanations!...

Show More

A.C. Fundamentals - Unbalanced Load
Answer : In the context of electrical engineering, A.C. (alternating current) fundamentals refer to the principles and concepts related to alternating current systems. An unbalanced load refers to ... properly design, monitor, and maintain electrical systems to ensure balanced loads and optimal performance....

Show More

A.C. Fundamentals - Two Wattmeter Method
Answer : The Two Wattmeter Method is a technique used for measuring the power in a three-phase AC circuit. It is commonly employed in balanced and unbalanced three-phase systems to determine the ... measurements. It's important to follow safety guidelines when working with electrical circuits and equipment....

Show More

A.C. Fundamentals - True power
Answer : In the context of electrical engineering and AC (alternating current) fundamentals, "true power" refers to the actual power consumed by a circuit or device that is connected to an ... power represents the energy oscillating between the source and reactive components without performing useful work....

Show More

A.C. Fundamentals - Trigonometrical form
Answer : Trigonometric forms, also known as trigonometric representations or polar forms, are alternative ways to express complex numbers. A complex number is a number that comprises a real part and ... as these operations become simpler in trigonometric or exponential forms compared to the rectangular form....

Show More

A.C. Fundamentals - Transient Response in R-L-C Circuit
Answer : A.C. Fundamentals - Transient Response in R-L-C Circuit In the realm of AC (alternating current) circuits, the behavior of circuits with resistors (R), inductors (L), and ... understanding. Detailed calculations, Laplace transforms, and differential equations are often used for in-depth analysis....

Show More

A.C. Fundamentals - Time period and frequency
Answer : In the realm of electrical engineering and physics, alternating current (AC) is a type of electrical current where the direction of the current periodically reverses. Two fundamental ... analyzing AC circuits, including topics like waveform generation, signal processing, and power distribution....

Show More

A.C. Fundamentals - Time period
Answer : In the context of A.C. (alternating current) fundamentals, the term "time period" refers to a fundamental parameter of an AC waveform. Alternating current is characterized by its periodic ... , calculating phase differences, and determining the behavior of AC signals in different types of circuits....

Show More

A.C. Fundamentals - T-section
Answer : T-section, also known as T-network, is a type of electrical circuit configuration often used in electronics and electrical engineering. It is commonly used in filter design and impedance matching ... Pi-sections, L-sections, and more complex networks like Butterworth, Chebyshev, and Bessel filters....

Show More

A.C. Fundamentals - Susceptance-frequency curve
Answer : The Susceptance-frequency curve, also known as the B-f curve, is a graphical representation of how the susceptance (B) of a circuit component or network changes with respect to frequency. ... in a circuit interact and how they affect the overall behavior of the circuit at different frequencies....

Show More

A.C. Fundamentals - Subtraction of Alternating Quantities
Answer : Subtraction of alternating quantities in AC (alternating current) circuits involves applying the same principles as subtraction in DC circuits but taking into account the complex nature of AC voltages ... complex scenarios, such as using phasor diagrams or complex algebra to solve circuit problems....

Show More

A.C. Fundamentals - Step Response of R-L-C Circuit
Answer : The step response of an R-L-C circuit refers to how the circuit's output voltage or current responds when a step input voltage is applied to it. An R-L-C circuit is ... Understanding these parameters and the behavior of the circuit helps in designing and analyzing circuits for various applications....

Show More

A.C. Fundamentals - Step Response of R-L-C Circuit
Answer : The step response of an R-L-C circuit refers to how the circuit behaves when a sudden change, or step, is applied to its input voltage or current. The response is characterized by the ... insights into how the circuit responds to sudden changes and how it eventually settles into a stable state....

Show More

A.C. Fundamentals - Step Response of R-L Circuit
Answer : In electrical engineering, the step response of a circuit is the behavior of the circuit when subjected to a sudden change in input, typically from zero to a constant value (step input). ... in the inductor's windings, or mutual inductance if multiple inductors are present in the circuit....

Show More

A.C. Fundamentals - Step Response of R-C Circuit
Answer : The step response of an R-C (resistor-capacitor) circuit refers to the behavior of the circuit when a sudden change, or step, in input voltage is applied. This behavior is especially ... or discharging of the capacitor, and this behavior is characterized by the time constant of the circuit....

Show More

A.C. Fundamentals - Star Connection
Answer : In electrical engineering, AC (alternating current) fundamentals refer to the basic principles and concepts related to alternating current systems. One important aspect of AC systems is the different ... in scenarios where a neutral point is needed for grounding and maintaining system stability....

Show More

A.C. Fundamentals - Star Connected Load
Answer : In the context of electrical engineering and AC (alternating current) fundamentals, a "Star Connected Load" refers to a specific configuration of three-phase electrical loads. Three-phase AC ... between them depends on the specific requirements of the electrical system and the connected devices....

Show More

A.C. Fundamentals - Some Cases of Parallel Connected Elements
Answer : In the realm of electrical engineering and circuit theory, parallel-connected elements are components that are connected across the same two nodes, sharing the same voltage difference. Here are some ... , so it's important to apply the appropriate formulas and techniques to simplify the analysis....

Show More

A.C. Fundamentals - Sinusoidal Function
Answer : Certainly, I can help you with AC (alternating current) fundamentals and sinusoidal functions. AC Fundamentals: Alternating current (AC) is an electric current that periodically reverses direction. It is ... working with AC electricity, as it forms the basis for AC circuit analysis and design....

Show More

A.C. Fundamentals - Sinusoidal Alternating Voltage and Current
Answer : Certainly, I'd be happy to explain the basics of sinusoidal alternating voltage and current, which are fundamental concepts in the study of electrical circuits and systems. Sinusoidal Alternating ... designing and analyzing electrical circuits, as well as for working with electrical power systems....

Show More

A.C. Fundamentals - Sine Waveform
Answer : Alternating Current (AC) fundamentals are essential concepts in electrical engineering, and one of the fundamental AC waveforms is the sine wave. A sine wave is a smooth, periodic ... analyzing and designing AC circuits, working with electrical systems, and various other engineering applications....

Show More

A.C. Fundamentals - Significance of Power Factor
Answer : Power factor is a critical concept in AC (alternating current) electrical systems and plays a significant role in the efficient and reliable operation of various electrical devices and systems. ... efforts to improve power factor can result in substantial benefits for both consumers and utilities....

Show More

A.C. Fundamentals - Significance of Operator j
Answer : In electrical engineering and physics, the operator "j" is commonly used to represent the imaginary unit, which is equal to the square root of -1. In other fields of mathematics and ... numbers and phasor notation, facilitating the analysis, design, and operation of AC circuits and systems....

Show More

A.C. Fundamentals - Sharpness of Resonance
Answer : In the context of A.C. (alternating current) fundamentals, "sharpness of resonance" refers to the degree to which a resonant circuit or system can amplify a specific frequency of ... . The sharpness of resonance allows for precise frequency selection and filtering in various electronic systems....

Show More

A.C. Fundamentals - Series-to-Parallel Conversion and Vice-Versa
Answer : Converting electrical circuits from series to parallel or vice-versa is a common task in electrical engineering. Series and parallel circuits have distinct properties, and the conversion ... and circuit configurations to ensure they meet the desired electrical specifications and requirements....

Show More

A.C. Fundamentals - Series-Parallel A.C. Circuits
Answer : A.C. (alternating current) fundamentals play a crucial role in understanding electrical circuits, both in series and parallel configurations. Let's delve into series-parallel A.C. ... relationships between currents, voltages, impedances, and phasors to effectively analyze and design circuits....

Show More

A.C. Fundamentals - Series Resonance
Answer : Certainly, I can help you understand series resonance in A.C. (alternating current) circuits! Series resonance is a phenomenon that occurs in circuits that consist of a resistor (R), ... -world scenarios, components have tolerances and parasitic effects that can affect the behavior of the circuit....

Show More

A.C. Fundamentals - Series R-L-C Circuit
Answer : A.C. fundamentals refer to the principles and concepts related to alternating current (A.C.) circuits. A series R-L-C circuit is a type of A.C. circuit that consists of a resistor ( ... , where A.C. circuits are commonly used in applications like filters, tuning circuits, and impedance matching....

Show More

A.C. Fundamentals - Series R-C Circuit
Answer : A series R-C circuit is an electrical circuit that consists of a resistor (R) and a capacitor (C) connected in series to a voltage source (generally an AC voltage source). ... , makes this circuit configuration valuable for applications like filtering high-frequency noise and generating time delays....

Show More

A.C. Fundamentals - Root Mean Square (R.M.S.) Value of Alternating Current
Answer : In alternating current (AC) circuits, the Root Mean Square (RMS) value is a crucial parameter that helps us understand the equivalent steady DC value of an AC waveform. It's a way to ... AC quantities are consistent with their DC equivalents, making analysis and design of AC systems more manageable....

Show More

A.C. Fundamentals - Resonance in Parallel A.C. Circuits (Parallel Resonance)
Answer : Parallel resonance, also known as anti-resonance, is a phenomenon that occurs in parallel AC circuits when the impedance of the circuit is minimized and the current flowing through the ... of electronics and electrical engineering, as it provides insights into circuit behavior and performance....

Show More

A.C. Fundamentals - Resonance in A.C. Circuits
Answer : Resonance in AC circuits is a phenomenon that occurs when the inductive reactance (XL) and capacitive reactance (XC) in a circuit become equal, resulting in a condition where the ... and capacitors. It allows engineers to optimize circuit performance for specific frequency ranges and applications....

Show More

A.C. Fundamentals - Resonance Curve
Answer : Sure, I'd be happy to explain A.C. fundamentals and the resonance curve. A.C. Fundamentals: Alternating Current (A.C.) is an electric current that reverses direction ... response amplitude in circuits with reactive components, showing the phenomenon of resonance at the resonant frequency....

Show More

A.C. Fundamentals - Resonance between Parallel R-L and R-C Circuit
Answer : Resonance is an important concept in AC (alternating current) circuits, particularly when dealing with parallel R-L (resistor-inductor) and R-C (resistor-capacitor) circuits. Resonance occurs when the ... real impedance. This leads to a peak in current and/or voltage at the resonant frequency....

Show More

A.C. Fundamentals - Resistance Element
Answer : In the context of electrical engineering and circuits, the term "A.C. fundamentals" typically refers to the basics of alternating current (A.C.) circuits. One important component of A.C. circuits is ... circuits, whether they are based on direct current (D.C.) or alternating current (A.C.)....

Show More

A.C. Fundamentals - Representation of E.M.F. Equations
Answer : In the context of electrical engineering, A.C. fundamentals refer to the study of alternating current (AC) circuits and the principles governing them. One important concept in AC circuits ... understanding the behavior of AC circuits, combining resistance and reactance in a single complex quantity....

Show More

A.C. Fundamentals - Representation of Alternating Voltages and Currents
Answer : Alternating Current (AC) fundamentals refer to the basic principles and concepts associated with alternating voltages and currents. In electrical systems, AC is the type of current that ... the basis for analyzing and designing AC circuits, transformers, generators, and transmission lines....

Show More

A.C. Fundamentals - Relationship Among Z, 6, and Q
Answer : It seems like you're asking about the relationship among impedance (Z), resistance (R), reactance (X), and quality factor (Q) in AC (alternating current) circuits. Let me break down ... a measure of the relative magnitude of reactance to resistance in a circuit, particularly in resonant circuits....

Show More

A.C. Fundamentals - Relation between step response and impulse response
Answer : In the context of linear time-invariant (LTI) systems in electrical engineering, both the step response and the impulse response are important concepts that describe how a system behaves in ... used to analyze and design various types of systems, including electronic circuits and control systems....

Show More

A.C. Fundamentals - Rectangular form.
Answer : Alternating Current (AC) fundamentals in the context of electrical engineering refer to the study of electrical currents that periodically change direction. AC is commonly used for power ... simplifies AC circuit analysis and calculations, making it easier to handle sinusoidal behaviors....

Show More

A.C. Fundamentals - Real or True Power
Answer : A.C. fundamentals, specifically related to electrical power, involve several important concepts, including real power, apparent power, and reactive power. Let's focus on the concept of real power: ... to perform useful work, and it is crucial for efficient and effective electrical system operation....

Show More
...