🔍
Measurement and Instrumentation - Ballistic Galvanometer

1 Answer

A ballistic galvanometer is an instrument used to measure the total quantity of electricity (electric charge) passed through a circuit. It is a type of moving-coil galvanometer that is specifically designed to measure the charge associated with transient currents, such as those generated by sudden discharges or impulses. The instrument is named "ballistic" because it is used to measure the "ballistic charge" resulting from a rapid change in current.

Key features of a ballistic galvanometer:

Damping: Unlike conventional galvanometers that are heavily damped to show the steady-state current, a ballistic galvanometer is minimally damped. This allows the galvanometer's needle to oscillate freely in response to the transient current.

Coil Design: The galvanometer features a coil suspended in a magnetic field. When a transient current flows through the coil, it generates a magnetic field that interacts with the existing magnetic field, causing the coil to move.

Measurement Principle: The deflection of the coil is proportional to the quantity of charge passing through it. The coil deflects to a certain angle and then oscillates back and forth before coming to rest due to the minimal damping. The maximum deflection angle is used to calculate the total charge.

Ballistic Constant: The instrument has a ballistic constant that relates the coil constant, the moment of inertia of the coil, and other parameters of the galvanometer. This constant is crucial for converting the deflection angle into the quantity of charge.

Applications of a ballistic galvanometer:

Measurement of Current: Ballistic galvanometers are used to measure transient currents, such as those produced by the discharge of capacitors or inductive circuits. They can be used in high-speed circuits where conventional galvanometers would be unable to provide accurate measurements.

Electrical Testing: They are used in experiments and tests involving sudden changes in current, like in the calibration of impulse generators or in investigations related to electrical breakdown phenomena.

Circuit Analysis: In studies involving electrical circuits with rapid changes, ballistic galvanometers can help researchers understand the transient behavior of the circuits.

It's important to note that while ballistic galvanometers were historically important instruments, modern digital measurement methods have largely replaced them due to their limited accuracy and the availability of more advanced technology.

Please remember that my information might be based on knowledge up until September 2021, and there might have been developments or changes in the field of measurement and instrumentation since then.
0 like 0 dislike

Related questions

Measurement and Instrumentation - Vibration Galvanometer
Answer : A vibration galvanometer is an electromechanical instrument used to measure small electrical currents. It is commonly used in applications where precise current measurements are needed, such as in laboratory ... ease of use, greater precision, and reduced susceptibility to mechanical wear and tear....

Show More

Magnetic Circuit and Electromagnetism - B-H Curve by Ballistic Galvanometer
Answer : Magnetic circuits and the B-H curve are concepts related to electromagnetism and play a significant role in understanding the behavior of magnetic materials and devices like electromagnets and transformers. A ... electric charge and is not directly related to magnetic circuits or the B-H curve....

Show More

Magnetic Circuit and Electromagnetism - B-H Curve by Ballistic Galvanometer
Answer : It seems like you're interested in the topics of magnetic circuits, electromagnetism, and the B-H curve, particularly in relation to a ballistic galvanometer. Let's break down ... in understanding magnetic circuits, electromagnetism, and the behavior of magnetic materials under varying conditions....

Show More

Measurement and Instrumentation - Working Standards
Answer : Working standards in the context of measurement and instrumentation refer to the reference instruments, equipment, or artifacts that are used as the basis for calibrating or verifying other measurement ... , chemistry, and more. They form the foundation of traceable and accurate measurement systems....

Show More

Measurement and Instrumentation - Wattmeters
Answer : Certainly, I'd be happy to provide information about wattmeters and their role in measurement and instrumentation. A wattmeter is an electrical instrument used to measure the power ... and generation accurately, which is essential for efficient and reliable operation of electrical systems....

Show More

Measurement and Instrumentation - Wattmeter ratings
Answer : Wattmeters are instruments used to measure electrical power in a circuit. They are particularly useful for both AC and DC circuits to determine the power consumed or delivered by a load. ... to the manufacturer's specifications and guidelines when selecting a wattmeter for your measurement needs....

Show More

Measurement and Instrumentation - Wattmeter Errors
Answer : Wattmeters are instruments used to measure the power consumed or generated in an electrical circuit. They work by measuring the product of voltage, current, and the power factor of the ... refer to the manufacturer's documentation for guidance on calibration, usage, and error correction techniques....

Show More

Measurement and Instrumentation - Voltmeter Sensitivity
Answer : Voltmeter sensitivity, in the context of measurement and instrumentation, refers to the ability of a voltmeter to detect and measure small changes in voltage accurately. It is an important ... also play important roles in determining the suitability of a voltmeter for a given application....

Show More

Measurement and Instrumentation - Volt Ratio Box
Answer : A Volt Ratio Box, also known as a Voltage Divider Box or Voltage Ratio Box, is a precision instrument used in electrical measurement and calibration processes. It is designed to provide accurate ... so there may have been advancements or changes in technology related to Volt Ratio Boxes since then....

Show More

Measurement and Instrumentation - Vibrating-Reed Frequency meter
Answer : A Vibrating-Reed Frequency Meter, also known as a Reed Frequency Meter or Reed Vibrator, is a type of mechanical instrument used to measure the frequency of an alternating current (AC) ... might have been further advancements or changes in the field of measurement and instrumentation since then....

Show More

Measurement and Instrumentation - Various Scales
Answer : Measurement and instrumentation involve the process of quantifying physical quantities and characteristics using various instruments and devices. Different types of scales are used to represent these ... important to choose the appropriate scale based on the characteristics of the data....

Show More

Measurement and Instrumentation - Variable Inductance transducers
Answer : Variable inductance transducers are a type of sensor or transducer used to measure physical quantities by exploiting the relationship between inductance and the quantity being measured. Inductance ... available for measuring various physical quantities, each with its own advantages and limitations....

Show More

Measurement and Instrumentation - Types of Secondary Instruments
Answer : Secondary instruments, also known as secondary measuring instruments or secondary measuring devices, are devices used in measurement and instrumentation to indirectly measure various physical quantities ... role in accurately measuring and monitoring various physical quantities in diverse fields....

Show More

Measurement and Instrumentation - Types of Oscilloscopes
Answer : Oscilloscopes are electronic test instruments used to visualize and analyze the waveform of electronic signals. They are essential tools for engineers, technicians, and researchers working in various ... oscilloscope technology continues to evolve, so new types and features may emerge over time....

Show More

Measurement and Instrumentation - True Value
Answer : In the field of measurement and instrumentation, "true value" refers to the actual, accurate, and theoretically perfect value of a physical quantity being measured. It represents the quantity's ... and instruments to approach the true value as closely as possible for reliable and accurate results....

Show More

Measurement and Instrumentation - Transducers and Their Applications
Answer : Measurement and instrumentation play a crucial role in various fields, allowing us to quantify and monitor physical quantities accurately. Transducers are a fundamental component of ... and broad applicability make them essential components in advancing technology and scientific understanding....

Show More

Measurement and Instrumentation - Three-phase Wattmeter
Answer : A three-phase wattmeter is an instrument used to measure the total power or energy consumed in a balanced or unbalanced three-phase electrical system. It provides an accurate measurement of ... current transformers, the calibration of the instrument, and the overall design of the measurement setup....

Show More

Measurement and Instrumentation - Three-Phase Watthour Meter
Answer : A three-phase watthour meter, also known as an electricity meter or energy meter, is an instrument used to measure and record the energy consumption of three-phase electrical systems ... consumption in three-phase electrical systems, contributing to fair and transparent energy usage practices....

Show More

Measurement and Instrumentation - Thermocouple Instruments
Answer : Thermocouples are temperature sensors that work based on the principle of the Seebeck effect, where a voltage difference is generated between two different metals joined at one end when there ... The choice of instrument and thermocouple type depends on the specific requirements of the application....

Show More

Measurement and Instrumentation - Thermistors
Answer : Thermistors are temperature-sensitive resistors that exhibit a significant change in their electrical resistance with temperature variations. They are widely used in measurement and control ... changes, making them ideal for applications requiring precise temperature monitoring and control....

Show More

Measurement and Instrumentation - Sum of Two or More Quantities
Answer : In the context of measurement and instrumentation, the concept of "sum of two or more quantities" usually refers to the mathematical addition of numerical values representing those quantities. ... to consider the accuracy, precision, and units of measurement when working with multiple quantities....

Show More

Measurement and Instrumentation - Static Sensitivity
Answer : Static sensitivity, in the context of measurement and instrumentation, refers to the ratio of the change in the output of a measurement instrument or sensor to a corresponding change in the ... an instrument's ability to accurately respond to changes in the input quantity being measured....

Show More

Measurement and Instrumentation - Static Error
Answer : In the field of measurement and instrumentation, static error refers to the deviation or discrepancy between the measured value obtained from a measuring instrument and the true or ... Understanding and managing these errors are crucial for obtaining reliable and meaningful measurement results....

Show More

Measurement and Instrumentation - Standards
Answer : Measurement and instrumentation standards are established guidelines and specifications that define how measurements should be made and how instruments should be designed, calibrated, and used to ... context adhere to the relevant standards to maintain accuracy, consistency, and comparability....

Show More

Measurement and Instrumentation - Spring Control method
Answer : "Spring control method" in the context of measurement and instrumentation typically refers to a control mechanism that utilizes springs to regulate or adjust certain parameters in a system. ... control method depends on the specific requirements and characteristics of the system being controlled....

Show More

Measurement and Instrumentation - Split Phase Type
Answer : Split-phase is a type of single-phase electrical power distribution system. It is commonly used in residential and small commercial settings to provide power to single-phase loads such as ... the proper functioning of the split-phase system, ensuring safety, and optimizing its efficiency....

Show More

Measurement and Instrumentation - Sources of Errors in Moving Iron Instruments
Answer : Moving iron instruments are commonly used in measurement and instrumentation to measure various electrical quantities like voltage and current. However, like any measurement device, they are ... the potential error sources are crucial to ensure accurate measurements using moving iron instruments....

Show More

Measurement and Instrumentation - Sources of errors in Dynamometer Type Instruments
Answer : Dynamometer-type instruments are commonly used for measuring mechanical quantities like torque and power. They operate based on the principle of measuring the deflection or strain produced in a ... methods can be employed to mitigate some of these errors in dynamometer-type instruments....

Show More

Measurement and Instrumentation - Single-Phase Induction Watthour Meters or Energy Meters
Answer : Single-phase induction watt-hour meters, also known as energy meters, are commonly used to measure and record the electrical energy consumed by a single-phase load over a given period of time ... compatibility with various load types, and ability to provide real-time data to utilities and consumers....

Show More

Measurement and Instrumentation - Single-Phase Electrodynamic Power Factor Meter
Answer : A single-phase electrodynamic power factor meter is an instrument used to measure the power factor of a single-phase AC electrical system. Power factor is a measure of how effectively ... power factor meter still apply and can serve as a foundation for understanding power factor measurement....

Show More

Measurement and Instrumentation - Shaded Pole Type
Answer : The Shaded Pole Type is a design commonly used in single-phase AC induction motors and some types of transformers. It's a simple and cost-effective method of creating a rotating magnetic ... simple construction and low cost, but they have limitations in terms of efficiency and starting torque....

Show More

Measurement and Instrumentation - Secondary Standards
Answer : In the field of measurement and instrumentation, standards play a crucial role in ensuring accuracy, consistency, and comparability of measurements. Secondary standards are an essential ... measurement infrastructure, contributing to the reliability and consistency of measurements in various fields....

Show More

Measurement and Instrumentation - Secondary Instruments
Answer : Secondary instruments in the context of measurement and instrumentation typically refer to devices that are used to measure and display the values of various physical quantities. Unlike primary ... accurate and specialized, secondary instruments are valuable tools for a wide range of applications....

Show More

Measurement and Instrumentation - Resistance Transducer
Answer : A resistance transducer, also known as a resistive sensor or resistive transducer, is a type of sensor used to measure physical quantities by exploiting changes in electrical resistance. ... material used, the manufacturing process, the operating conditions, and the calibration methods employed....

Show More

Measurement and Instrumentation - Resistance Thermometers
Answer : Resistance thermometers, also known as resistance temperature detectors (RTDs) or platinum resistance thermometers (PRTs), are types of temperature sensors that operate based on the ... temperature measurements, making them essential tools in many critical industrial and scientific processes....

Show More

Measurement and Instrumentation - Resistance Thermometers
Answer : Resistance thermometers, also known as resistance temperature detectors (RTDs), are devices used to measure temperature by correlating the resistance of the RTD element with temperature. They are ... and reliability, making them suitable for a wide range of applications across different industries....

Show More

Measurement and Instrumentation - Resistance of voltmeter
Answer : In the context of measurement and instrumentation, a voltmeter is an instrument used to measure the voltage or potential difference between two points in an electric circuit. The resistance of a ... for the proper use of a voltmeter to ensure accurate measurements in different circuit scenarios....

Show More

Measurement and Instrumentation - Resistance of ammeter
Answer : An ammeter is an instrument used to measure electric current. It is designed to be connected in series with the circuit through which the current is flowing. When an ammeter is connected, it ... should be as low as possible and much smaller than the resistance of the circuit being measured....

Show More

Measurement and Instrumentation - Repulsion (or Double-iron) Type
Answer : The Repulsion or Double-Iron Type is a classification of instrument used in measurement and instrumentation. This type of instrument is commonly employed in electrical measurements, particularly in ... may be variations in design and construction based on the specific application and manufacturer....

Show More

Measurement and Instrumentation - Reproducibility
Answer : Reproducibility in the context of measurement and instrumentation refers to the ability to obtain consistent and similar results when a measurement or experiment is repeated by different individuals ... documentation, uncertainty analysis, quality control, and the sharing of data and methodologies....

Show More

Measurement and Instrumentation - Repeatability
Answer : Repeatability, in the context of measurement and instrumentation, refers to the ability of a measurement instrument or system to provide consistent and close results when measuring the same quantity multiple ... the measured value is to the true or reference value of the quantity being measured....

Show More

Measurement and Instrumentation - Remanance
Answer : It seems like you're interested in the topic of "Remanance" within the context of Measurement and Instrumentation. Remanance refers to the residual magnetic induction that remains in a ... the need for careful calibration, measurement techniques, and data analysis to ensure accurate results....

Show More

Measurement and Instrumentation - Relative Static Error
Answer : Relative static error, also known as relative error or relative uncertainty, is a concept used in measurement and instrumentation to quantify the accuracy or precision of a measurement compared to the true ... of a measurement, it's important to consider these other sources of error as well....

Show More

Measurement and Instrumentation - Relative Limiting Errors
Answer : Relative Limiting Error in the context of Measurement and Instrumentation refers to the maximum permissible error allowed in a measurement, expressed as a fraction or percentage of the full-scale ... the instrument's readings and aids in making informed decisions based on the measurements taken....

Show More

Measurement and Instrumentation - Ranges of DC ammeters and DC voltmeters in Dynamometer Type
Answer : In a dynamometer-type instrument, which is often used for measuring both DC currents (ammeters) and DC voltages (voltmeters), the range of measurement refers to the span of values that the ... it's crucial to choose a range that closely matches the expected value to ensure accurate readings....

Show More

Measurement and Instrumentation - Ranges of DC ammeters and DC voltmeters
Answer : Measurement and instrumentation involve the use of various instruments to measure different quantities accurately. DC ammeters and DC voltmeters are instruments used to measure direct current (DC) ... . Always refer to the manufacturer's specifications and guidelines when using these instruments....

Show More

Measurement and Instrumentation - Ranges of Attraction (or Single-iron) Type
Answer : "Range of Attraction," often referred to as "Single-iron" type in the context of measurement and instrumentation, typically pertains to a type of instrument used to measure magnetic fields. ... the "Single-iron" type, can still provide insights into the historical development of instrumentation....

Show More

Measurement and Instrumentation - Range of vibrating Reed frequency meter
Answer : A vibrating reed frequency meter, also known as a resonant reed frequency meter or simply a reed frequency meter, is a type of mechanical frequency meter used to measure the frequency of ... , you would need to consult the manufacturer's specifications or technical documentation for that instrument....

Show More

Measurement and Instrumentation - Range of Induction Wattmeters
Answer : Induction wattmeters are instruments used for measuring electrical power in AC circuits. They work on the principle of electromagnetic induction and are commonly used to measure power in industrial and ... s best to refer to the manufacturer's specifications or user manual for detailed information....

Show More

Measurement and Instrumentation - Range extension of thermocouple
Answer : Range extension of a thermocouple refers to the process of extending its temperature measurement capabilities beyond its inherent limitations. Thermocouples are temperature sensors that generate a voltage ... as sensor drift, noise, and environmental conditions that can affect measurement accuracy....

Show More
...