🔍
Measurement and Instrumentation - Measurement of Self Inductance

1 Answer

Measurement of self-inductance is a fundamental aspect of electrical engineering and is crucial for understanding and designing circuits involving inductors. Self-inductance is a property of a circuit component (usually an inductor) that represents its ability to oppose changes in the current flowing through it. The unit of self-inductance is the henry (H).

Here are the basic methods for measuring self-inductance:

Bridge Method:
One common method for measuring self-inductance is the bridge method, which uses a Wheatstone bridge configuration. In this method, the inductor whose self-inductance is to be measured is connected in one arm of the bridge. By adjusting the resistors in the other arms of the bridge, a balance condition is achieved, and the self-inductance can be calculated using the bridge equation.

RL Time Constant Method:
This method involves connecting the inductor in series with a known resistance (R) to form an RL circuit. A step voltage is applied to the circuit, and the time constant of the resulting exponential rise in current is measured. By knowing the resistance and the time constant, the self-inductance can be calculated using the formula L = R * τ.

Oscillator and Lissajous Figure Method:
In this method, an oscillator circuit that includes the inductor and a capacitor is used. The frequency of the oscillator is adjusted until a Lissajous figure (a graphical representation of the phase relationship between two oscillating signals) is formed on an oscilloscope. The self-inductance can be calculated using the formula L = (1 / (4π²f²C)), where f is the frequency and C is the capacitance.

RLC Resonance Method:
Another method involves creating a series RLC circuit (resistor, inductor, and capacitor) and sweeping the frequency of an AC source. When the circuit reaches resonance, the impedance of the circuit becomes purely resistive, and the resonant frequency can be used to calculate the self-inductance.

Mutual Inductance Compensation Method:
In this method, two coils are used – one with a known self-inductance and another with the inductor whose self-inductance is to be measured. By adjusting the currents through the coils and measuring the resulting voltages, the self-inductance can be calculated based on the known mutual inductance between the coils.

Remember that accuracy is crucial in these measurements, and factors like stray capacitance, resistance, and mutual inductance can introduce errors. Depending on the available equipment and the desired accuracy, the appropriate method can be chosen. Always make sure to follow proper safety procedures when working with electrical circuits and equipment.
0 like 0 dislike

Related questions

Measurement and Instrumentation - Deflecting torque of M.I. Instruments in Terms of Self-Inductance
Answer : In the context of measurement and instrumentation, specifically when discussing moving coil instruments (M.I. instruments), the concept of deflecting torque and its relation to self-inductance ... the magnetic circuit, and other practical considerations that might affect the instrument's behavior....

Show More

Measurement and Instrumentation - Variable Inductance transducers
Answer : Variable inductance transducers are a type of sensor or transducer used to measure physical quantities by exploiting the relationship between inductance and the quantity being measured. Inductance ... available for measuring various physical quantities, each with its own advantages and limitations....

Show More

Measurement and Instrumentation - Measurement of Mutual Inductance
Answer : Measurement of mutual inductance is an important aspect of electrical engineering and is often used in various applications involving transformers, inductors, and other magnetic components. Mutual inductance ... of the coils being measured, different methods and techniques might be more suitable....

Show More

Measurement and Instrumentation - Maxwell's Inductance-Capacitance Bridge
Answer : Maxwell's Inductance-Capacitance Bridge, also known as Maxwell's Bridge, is a type of AC bridge circuit used for measuring unknown inductances (L) and capacitances (C) by ... still serves as a historical example of bridge circuit applications in electrical measurements and instrumentation....

Show More

Measurement and Instrumentation - Maxwell's Inductance Bridge
Answer : Maxwell's Inductance Bridge is a type of bridge circuit used for measuring inductance. It was developed based on the principles of a Wheatstone bridge, which is a well-known ... note that modern measurement techniques have largely superseded these bridge circuits in many practical situations....

Show More

Measurement and Instrumentation - Deflecting Torque (Td) of Dynamometer Type Instruments in Terms of Mutual Inductance
Answer : In dynamometer-type instruments, deflecting torque (Td) is the torque applied to the moving coil of the instrument due to the current flowing through it. The deflecting torque is ... . Also, real-world instruments might have additional complexities and factors that influence their behavior....

Show More

Measurement and Instrumentation - Advantages and Disadvantages of Maxwell's inductance capacitance bridge
Answer : Maxwell's Inductance-Capacitance (LC) Bridge is a type of bridge circuit used for measuring unknown inductances and capacitances. It's commonly used in electrical engineering for precision ... important to weigh its advantages and disadvantages against the specific measurement needs and conditions....

Show More

Measurement and Instrumentation - Working Standards
Answer : Working standards in the context of measurement and instrumentation refer to the reference instruments, equipment, or artifacts that are used as the basis for calibrating or verifying other measurement ... , chemistry, and more. They form the foundation of traceable and accurate measurement systems....

Show More

Measurement and Instrumentation - Wattmeters
Answer : Certainly, I'd be happy to provide information about wattmeters and their role in measurement and instrumentation. A wattmeter is an electrical instrument used to measure the power ... and generation accurately, which is essential for efficient and reliable operation of electrical systems....

Show More

Measurement and Instrumentation - Wattmeter ratings
Answer : Wattmeters are instruments used to measure electrical power in a circuit. They are particularly useful for both AC and DC circuits to determine the power consumed or delivered by a load. ... to the manufacturer's specifications and guidelines when selecting a wattmeter for your measurement needs....

Show More

Measurement and Instrumentation - Wattmeter Errors
Answer : Wattmeters are instruments used to measure the power consumed or generated in an electrical circuit. They work by measuring the product of voltage, current, and the power factor of the ... refer to the manufacturer's documentation for guidance on calibration, usage, and error correction techniques....

Show More

Measurement and Instrumentation - Voltmeter Sensitivity
Answer : Voltmeter sensitivity, in the context of measurement and instrumentation, refers to the ability of a voltmeter to detect and measure small changes in voltage accurately. It is an important ... also play important roles in determining the suitability of a voltmeter for a given application....

Show More

Measurement and Instrumentation - Volt Ratio Box
Answer : A Volt Ratio Box, also known as a Voltage Divider Box or Voltage Ratio Box, is a precision instrument used in electrical measurement and calibration processes. It is designed to provide accurate ... so there may have been advancements or changes in technology related to Volt Ratio Boxes since then....

Show More

Measurement and Instrumentation - Vibration Galvanometer
Answer : A vibration galvanometer is an electromechanical instrument used to measure small electrical currents. It is commonly used in applications where precise current measurements are needed, such as in laboratory ... ease of use, greater precision, and reduced susceptibility to mechanical wear and tear....

Show More

Measurement and Instrumentation - Vibrating-Reed Frequency meter
Answer : A Vibrating-Reed Frequency Meter, also known as a Reed Frequency Meter or Reed Vibrator, is a type of mechanical instrument used to measure the frequency of an alternating current (AC) ... might have been further advancements or changes in the field of measurement and instrumentation since then....

Show More

Measurement and Instrumentation - Various Scales
Answer : Measurement and instrumentation involve the process of quantifying physical quantities and characteristics using various instruments and devices. Different types of scales are used to represent these ... important to choose the appropriate scale based on the characteristics of the data....

Show More

Measurement and Instrumentation - Types of Secondary Instruments
Answer : Secondary instruments, also known as secondary measuring instruments or secondary measuring devices, are devices used in measurement and instrumentation to indirectly measure various physical quantities ... role in accurately measuring and monitoring various physical quantities in diverse fields....

Show More

Measurement and Instrumentation - Types of Oscilloscopes
Answer : Oscilloscopes are electronic test instruments used to visualize and analyze the waveform of electronic signals. They are essential tools for engineers, technicians, and researchers working in various ... oscilloscope technology continues to evolve, so new types and features may emerge over time....

Show More

Measurement and Instrumentation - True Value
Answer : In the field of measurement and instrumentation, "true value" refers to the actual, accurate, and theoretically perfect value of a physical quantity being measured. It represents the quantity's ... and instruments to approach the true value as closely as possible for reliable and accurate results....

Show More

Measurement and Instrumentation - Transducers and Their Applications
Answer : Measurement and instrumentation play a crucial role in various fields, allowing us to quantify and monitor physical quantities accurately. Transducers are a fundamental component of ... and broad applicability make them essential components in advancing technology and scientific understanding....

Show More

Measurement and Instrumentation - Three-phase Wattmeter
Answer : A three-phase wattmeter is an instrument used to measure the total power or energy consumed in a balanced or unbalanced three-phase electrical system. It provides an accurate measurement of ... current transformers, the calibration of the instrument, and the overall design of the measurement setup....

Show More

Measurement and Instrumentation - Three-Phase Watthour Meter
Answer : A three-phase watthour meter, also known as an electricity meter or energy meter, is an instrument used to measure and record the energy consumption of three-phase electrical systems ... consumption in three-phase electrical systems, contributing to fair and transparent energy usage practices....

Show More

Measurement and Instrumentation - Thermocouple Instruments
Answer : Thermocouples are temperature sensors that work based on the principle of the Seebeck effect, where a voltage difference is generated between two different metals joined at one end when there ... The choice of instrument and thermocouple type depends on the specific requirements of the application....

Show More

Measurement and Instrumentation - Thermistors
Answer : Thermistors are temperature-sensitive resistors that exhibit a significant change in their electrical resistance with temperature variations. They are widely used in measurement and control ... changes, making them ideal for applications requiring precise temperature monitoring and control....

Show More

Measurement and Instrumentation - Sum of Two or More Quantities
Answer : In the context of measurement and instrumentation, the concept of "sum of two or more quantities" usually refers to the mathematical addition of numerical values representing those quantities. ... to consider the accuracy, precision, and units of measurement when working with multiple quantities....

Show More

Measurement and Instrumentation - Static Sensitivity
Answer : Static sensitivity, in the context of measurement and instrumentation, refers to the ratio of the change in the output of a measurement instrument or sensor to a corresponding change in the ... an instrument's ability to accurately respond to changes in the input quantity being measured....

Show More

Measurement and Instrumentation - Static Error
Answer : In the field of measurement and instrumentation, static error refers to the deviation or discrepancy between the measured value obtained from a measuring instrument and the true or ... Understanding and managing these errors are crucial for obtaining reliable and meaningful measurement results....

Show More

Measurement and Instrumentation - Standards
Answer : Measurement and instrumentation standards are established guidelines and specifications that define how measurements should be made and how instruments should be designed, calibrated, and used to ... context adhere to the relevant standards to maintain accuracy, consistency, and comparability....

Show More

Measurement and Instrumentation - Spring Control method
Answer : "Spring control method" in the context of measurement and instrumentation typically refers to a control mechanism that utilizes springs to regulate or adjust certain parameters in a system. ... control method depends on the specific requirements and characteristics of the system being controlled....

Show More

Measurement and Instrumentation - Split Phase Type
Answer : Split-phase is a type of single-phase electrical power distribution system. It is commonly used in residential and small commercial settings to provide power to single-phase loads such as ... the proper functioning of the split-phase system, ensuring safety, and optimizing its efficiency....

Show More

Measurement and Instrumentation - Sources of Errors in Moving Iron Instruments
Answer : Moving iron instruments are commonly used in measurement and instrumentation to measure various electrical quantities like voltage and current. However, like any measurement device, they are ... the potential error sources are crucial to ensure accurate measurements using moving iron instruments....

Show More

Measurement and Instrumentation - Sources of errors in Dynamometer Type Instruments
Answer : Dynamometer-type instruments are commonly used for measuring mechanical quantities like torque and power. They operate based on the principle of measuring the deflection or strain produced in a ... methods can be employed to mitigate some of these errors in dynamometer-type instruments....

Show More

Measurement and Instrumentation - Single-Phase Induction Watthour Meters or Energy Meters
Answer : Single-phase induction watt-hour meters, also known as energy meters, are commonly used to measure and record the electrical energy consumed by a single-phase load over a given period of time ... compatibility with various load types, and ability to provide real-time data to utilities and consumers....

Show More

Measurement and Instrumentation - Single-Phase Electrodynamic Power Factor Meter
Answer : A single-phase electrodynamic power factor meter is an instrument used to measure the power factor of a single-phase AC electrical system. Power factor is a measure of how effectively ... power factor meter still apply and can serve as a foundation for understanding power factor measurement....

Show More

Measurement and Instrumentation - Shaded Pole Type
Answer : The Shaded Pole Type is a design commonly used in single-phase AC induction motors and some types of transformers. It's a simple and cost-effective method of creating a rotating magnetic ... simple construction and low cost, but they have limitations in terms of efficiency and starting torque....

Show More

Measurement and Instrumentation - Secondary Standards
Answer : In the field of measurement and instrumentation, standards play a crucial role in ensuring accuracy, consistency, and comparability of measurements. Secondary standards are an essential ... measurement infrastructure, contributing to the reliability and consistency of measurements in various fields....

Show More

Measurement and Instrumentation - Secondary Instruments
Answer : Secondary instruments in the context of measurement and instrumentation typically refer to devices that are used to measure and display the values of various physical quantities. Unlike primary ... accurate and specialized, secondary instruments are valuable tools for a wide range of applications....

Show More

Measurement and Instrumentation - Resistance Transducer
Answer : A resistance transducer, also known as a resistive sensor or resistive transducer, is a type of sensor used to measure physical quantities by exploiting changes in electrical resistance. ... material used, the manufacturing process, the operating conditions, and the calibration methods employed....

Show More

Measurement and Instrumentation - Resistance Thermometers
Answer : Resistance thermometers, also known as resistance temperature detectors (RTDs) or platinum resistance thermometers (PRTs), are types of temperature sensors that operate based on the ... temperature measurements, making them essential tools in many critical industrial and scientific processes....

Show More

Measurement and Instrumentation - Resistance Thermometers
Answer : Resistance thermometers, also known as resistance temperature detectors (RTDs), are devices used to measure temperature by correlating the resistance of the RTD element with temperature. They are ... and reliability, making them suitable for a wide range of applications across different industries....

Show More

Measurement and Instrumentation - Resistance of voltmeter
Answer : In the context of measurement and instrumentation, a voltmeter is an instrument used to measure the voltage or potential difference between two points in an electric circuit. The resistance of a ... for the proper use of a voltmeter to ensure accurate measurements in different circuit scenarios....

Show More

Measurement and Instrumentation - Resistance of ammeter
Answer : An ammeter is an instrument used to measure electric current. It is designed to be connected in series with the circuit through which the current is flowing. When an ammeter is connected, it ... should be as low as possible and much smaller than the resistance of the circuit being measured....

Show More

Measurement and Instrumentation - Repulsion (or Double-iron) Type
Answer : The Repulsion or Double-Iron Type is a classification of instrument used in measurement and instrumentation. This type of instrument is commonly employed in electrical measurements, particularly in ... may be variations in design and construction based on the specific application and manufacturer....

Show More

Measurement and Instrumentation - Reproducibility
Answer : Reproducibility in the context of measurement and instrumentation refers to the ability to obtain consistent and similar results when a measurement or experiment is repeated by different individuals ... documentation, uncertainty analysis, quality control, and the sharing of data and methodologies....

Show More

Measurement and Instrumentation - Repeatability
Answer : Repeatability, in the context of measurement and instrumentation, refers to the ability of a measurement instrument or system to provide consistent and close results when measuring the same quantity multiple ... the measured value is to the true or reference value of the quantity being measured....

Show More

Measurement and Instrumentation - Remanance
Answer : It seems like you're interested in the topic of "Remanance" within the context of Measurement and Instrumentation. Remanance refers to the residual magnetic induction that remains in a ... the need for careful calibration, measurement techniques, and data analysis to ensure accurate results....

Show More

Measurement and Instrumentation - Relative Static Error
Answer : Relative static error, also known as relative error or relative uncertainty, is a concept used in measurement and instrumentation to quantify the accuracy or precision of a measurement compared to the true ... of a measurement, it's important to consider these other sources of error as well....

Show More

Measurement and Instrumentation - Relative Limiting Errors
Answer : Relative Limiting Error in the context of Measurement and Instrumentation refers to the maximum permissible error allowed in a measurement, expressed as a fraction or percentage of the full-scale ... the instrument's readings and aids in making informed decisions based on the measurements taken....

Show More

Measurement and Instrumentation - Ranges of DC ammeters and DC voltmeters in Dynamometer Type
Answer : In a dynamometer-type instrument, which is often used for measuring both DC currents (ammeters) and DC voltages (voltmeters), the range of measurement refers to the span of values that the ... it's crucial to choose a range that closely matches the expected value to ensure accurate readings....

Show More

Measurement and Instrumentation - Ranges of DC ammeters and DC voltmeters
Answer : Measurement and instrumentation involve the use of various instruments to measure different quantities accurately. DC ammeters and DC voltmeters are instruments used to measure direct current (DC) ... . Always refer to the manufacturer's specifications and guidelines when using these instruments....

Show More
...