🔍
What is a thermistor?

1 Answer

A thermistor is a type of resistor whose electrical resistance changes significantly with temperature variations. The word "thermistor" is a combination of "thermal" and "resistor." These devices are designed to be sensitive to changes in temperature and are commonly used in temperature sensing and control applications.

The resistance of a thermistor typically decreases as the temperature increases (negative temperature coefficient or NTC thermistors) or increases as the temperature rises (positive temperature coefficient or PTC thermistors). NTC thermistors are more common and widely used.

Thermistors are made from various semiconductor materials, such as oxides of metals like nickel, manganese, cobalt, or iron. The choice of material affects the thermistor's characteristics, including the temperature range over which it operates and its sensitivity.

Due to their temperature-dependent resistance, thermistors can be used in a variety of applications, such as:

Temperature sensors: Thermistors are used in thermostats, weather stations, and other devices to monitor and control temperature.

Temperature compensation: They can be employed to compensate for temperature variations in electronic circuits, ensuring accurate performance over a range of temperatures.

Temperature control: In some heating or cooling systems, thermistors are used to regulate the temperature by turning on or off the heating/cooling elements as needed.

Overcurrent protection: Thermistors can be used as self-resetting fuses to protect circuits from excessive current and prevent damage.

Medical devices: They are used in various medical applications, such as temperature monitoring in patient care.

Thermistors are valued for their reliability, low cost, and ease of integration into electronic circuits, making them a popular choice for temperature sensing and control tasks in a wide range of industries and applications.
0 like 0 dislike

Related questions

What is a thermistor?
Answer : A thermistor is a type of temperature sensor that exhibits a change in resistance with variations in temperature. The name "thermistor" is a combination of "thermal" and "resistor." Unlike ... cost-effectiveness make them a popular choice for temperature sensing in a wide range of industries....

Show More

How does a thermistor change resistance with temperature variations for temperature sensing applications?
Answer : A thermistor is a type of temperature sensor that exhibits a significant change in resistance with variations in temperature. It belongs to the category of "resistive temperature sensors" and ... systems, and many more due to their high sensitivity and reliability in temperature measurements....

Show More

What is a monostable multivibrator (one-shot circuit)?
Answer : A monostable multivibrator, commonly known as a one-shot circuit or pulse generator, is a type of electronic circuit that produces a single output pulse of a specific duration in response to an ... applications where a single, controlled pulse is needed in response to an external event or trigger....

Show More

What is a parallel resonant frequency?
Answer : In the context of electrical circuits and resonance, a parallel resonant frequency (also known as anti-resonant frequency or parallel resonance frequency) is a specific frequency at ... Understanding the parallel resonant frequency is crucial for designing and analyzing these circuits effectively....

Show More

What is a sinusoidal oscillator's frequency stability?
Answer : The frequency stability of a sinusoidal oscillator refers to how well it can maintain a constant and accurate frequency over time. It is a measure of how much the oscillator's ... careful system design are essential to meet the specific frequency stability requirements of a particular application....

Show More

What is a phase-locked loop (PLL) with frequency division?
Answer : A Phase-Locked Loop (PLL) with frequency division is a type of electronic circuit that is used to generate stable and precise output signals with a frequency that is a multiple ... , electronic devices, and signal processing applications where stable and accurate frequency generation is required....

Show More

What is a PLL frequency synthesizer?
Answer : A PLL (Phase-Locked Loop) frequency synthesizer is an electronic circuit or system used to generate stable and precise frequencies based on a reference signal. It is a widely used technique ... low phase noise, and accurate frequency synthesis, making them crucial for many modern electronic systems....

Show More

What is a balanced modulator circuit?
Answer : A balanced modulator circuit is an electronic circuit used in analog signal processing and communications systems. Its primary function is to modulate a signal onto a carrier wave or ... of signals and helps maintain signal quality in communication systems by suppressing unwanted components....

Show More

What is an operational transconductance amplifier (OTA)?
Answer : An Operational Transconductance Amplifier (OTA) is an electronic device widely used in analog integrated circuits, particularly in applications involving analog signal processing and amplification. It is ... low-power, high-frequency, and high-gain applications in modern analog integrated circuits....

Show More

What is a transmission line termination?
Answer : A transmission line termination is an essential component in the field of electronics and telecommunications. It is used to match the impedance of a transmission line to the impedance of the ... in high-speed digital circuits, RF systems, and other applications where signal integrity is paramount....

Show More

What is a cascode voltage switch logic (CVSL) gate?
Answer : Cascode Voltage Switch Logic (CVSL) is a type of digital logic family used in integrated circuits (ICs) for implementing digital circuits. It is a variation of the conventional NMOS (N ... logic families, offers a viable option for certain applications where its advantages outweigh the drawbacks....

Show More

What is a JFET (Junction Field-Effect Transistor)?
Answer : A Junction Field-Effect Transistor (JFET) is a type of semiconductor device used in electronics as a voltage-controlled switch or amplifier. It falls under the category of field- ... applications. However, compared to bipolar transistors, JFETs generally have lower gain and transconductance values....

Show More

What is a decoupling capacitor?
Answer : A decoupling capacitor, also known as a bypass capacitor or a smoothing capacitor, is an electronic component used in electronic circuits to stabilize the voltage levels and remove ... for sensitive components, minimizing noise and voltage fluctuations and improving overall circuit performance....

Show More

What is a flash memory?
Answer : Flash memory is a type of non-volatile computer storage medium that can retain data even when the power supply is disconnected. It is used in various electronic devices, ... traditional mechanical hard drives in many portable electronic devices, significantly improving performance and reliability....

Show More

What is a voltage-controlled filter (VCF)?
Answer : A voltage-controlled filter (VCF) is an electronic circuit used in audio signal processing and synthesis to control the frequency content of a signal. It is a type of filter whose cutoff frequency ... timbral changes to the audio signal, making it a powerful tool for sound shaping and synthesis....

Show More

What is a superheterodyne receiver's intermediate frequency (IF)?
Answer : A superheterodyne receiver is a type of radio receiver widely used in modern communication devices. Its intermediate frequency (IF) is a fixed frequency that serves as an intermediate step in ... using an IF in a superheterodyne receiver remains a fundamental aspect of modern radio communication....

Show More

What is a monolithic microwave integrated circuit (MMIC) amplifier?
Answer : A Monolithic Microwave Integrated Circuit (MMIC) amplifier is a type of integrated circuit designed to operate at microwave frequencies, typically ranging from hundreds of megahertz (MHz) to ... continue to play a crucial role in enabling high-frequency communication and microwave-based systems....

Show More

What is a capacitance multiplier circuit?
Answer : A capacitance multiplier circuit is an electronic circuit designed to increase the effective capacitance in a circuit without physically adding more capacitors. It achieves this by using ... using physically larger capacitors or different filtering techniques might be more practical or efficient....

Show More

What is a switched capacitor filter?
Answer : A switched capacitor filter is an electronic filter used in signal processing and analog circuits to filter and shape analog signals. It is a type of active filter that uses capacitors ... limitations, they are widely used in integrated circuit designs where their advantages outweigh the drawbacks....

Show More

What is a negative feedback in amplifiers?
Answer : Negative feedback in amplifiers is a technique used to stabilize and improve the performance of electronic amplifiers. It involves feeding a portion of the output signal back to the ... carefully select the appropriate amount of feedback to optimize performance for the specific application....

Show More

What is an RF mixer circuit?
Answer : An RF (Radio Frequency) mixer circuit is an essential component in many communication systems and electronic devices. Its primary purpose is to combine two or more RF signals with different ... the combination of different RF signals to create new frequencies and perform frequency conversion tasks....

Show More

What is a Van de Graaff generator?
Answer : A Van de Graaff generator is a device that is used to generate static electricity. It was invented by American physicist Robert J. Van de Graaff in the 1920s. The generator typically consists ... as electric sparks from the generator can still be hazardous if proper safety measures are not observed....

Show More

What is an electronic compass sensor?
Answer : An electronic compass sensor, commonly known as a digital compass, is a device used to detect and measure the Earth's magnetic field and determine the direction or orientation ... applications, augmented reality, tilt compensation for accurate leveling, and enhanced location-based services....

Show More

What is a tri-state buffer (3-state buffer)?
Answer : A tri-state buffer, also known as a 3-state buffer, is a digital electronic component used in digital circuits and systems to control the flow of data. It has three possible output ... enter a high-impedance state is crucial in preventing conflicts and bus contention in complex digital systems....

Show More

What is a high-pass filter (HPF)?
Answer : A high-pass filter (HPF) is an electronic or signal processing filter that allows higher-frequency signals to pass through while attenuating or blocking lower-frequency signals. In other ... -pass filters (BPF) to create complex filtering responses that can suit specific application requirements....

Show More

What is a delta modulation (DM) ADC?
Answer : Delta modulation (DM) is a type of analog-to-digital conversion technique used to convert analog signals into digital form. The main principle behind delta modulation is to encode the difference ... , other ADC techniques like successive approximation (SAR) or delta-sigma ADCs are often preferred....

Show More

What is an H-bridge motor driver?
Answer : An H-bridge motor driver is an electronic circuit that allows a direct current (DC) motor to be controlled in both directions (forward and reverse) and also enables braking. It is called an "H- ... and low-side switches on at the same time) that can cause short circuits and damage the circuitry....

Show More

What is an LVDS (Low-Voltage Differential Signaling)?
Answer : Low-Voltage Differential Signaling (LVDS) is a signaling technology used for transmitting high-speed digital data over short distances while minimizing power consumption and electromagnetic ... , particularly in applications where signal integrity and noise immunity are critical considerations....

Show More

What is a gyrator-based inductor?
Answer : As of my last update in September 2021, a gyrator-based inductor is a type of electronic circuit that simulates the behavior of an inductor using active components such as operational ... good idea to consult more recent sources for the latest information on electronic components and circuits....

Show More

What is a memristor-based neural network?
Answer : A memristor-based neural network is a type of artificial neural network (ANN) that incorporates memristors as fundamental building blocks for its operations. A memristor is a specific type of ... potential to revolutionize the way we process information and build intelligent systems in the future....

Show More

What is a magnetic field sensor based on the magnetoresistive effect?
Answer : A magnetic field sensor based on the magnetoresistive effect is a type of sensor that utilizes the changes in electrical resistance of certain materials in response to an applied magnetic ... with high precision, making them valuable tools in various electronic devices and industrial applications....

Show More

What is a DC offset in an amplifier circuit?
Answer : In an amplifier circuit, a DC offset refers to a constant voltage that is present at the output of the amplifier, even when there is no input signal applied. Ideally, an amplifier should ... and test amplifier circuits to ensure that the DC offset is minimized and within safe operating limits....

Show More

What is an operational transconductance amplifier (OTA)?
Answer : An Operational Transconductance Amplifier (OTA) is a type of analog electronic device primarily used in integrated circuits (ICs) and electronic systems for various signal processing applications. It ... circuits, along with other components, to create more complex analog and mixed-signal systems....

Show More

What is a PNP transistor?
Answer : A PNP transistor is a type of bipolar junction transistor (BJT) that is widely used in electronic circuits for amplification and switching purposes. The term "PNP" stands for "Positive- ... electronic devices and circuits, such as audio amplifiers, voltage regulators, and digital logic circuits....

Show More

What is an NPN transistor?
Answer : An NPN transistor is a type of bipolar junction transistor (BJT), which is a three-terminal electronic device used in a wide range of electronic circuits. The term "NPN" refers ... suitable for various applications, such as amplification, switching, and signal processing in electronic circuits....

Show More

What is a thermocouple cold junction compensation?
Answer : Thermocouples are temperature sensors that work based on the principle of the Seebeck effect, which generates a voltage when there is a temperature difference between two junctions of ... by ambient temperature changes and ensures that the temperature readings are reliable and consistent....

Show More

What is an envelope tracking power amplifier?
Answer : An envelope tracking power amplifier (ETPA) is a type of power amplifier used in electronic devices to improve the efficiency of the power amplifier, especially in high-power ... is more commonly found in advanced communication devices and infrastructure rather than simple consumer electronics....

Show More

What is a Wien bridge oscillator with frequency modulation?
Answer : A Wien bridge oscillator is a type of electronic oscillator that generates sine waves. It typically consists of a feedback network containing a combination of resistors and capacitors in a ... synthesis, where frequency modulation is used to encode information or create interesting sound effects....

Show More

What is a Hall effect current sensor?
Answer : A Hall effect current sensor is a device used to measure electric current in a conductor without the need for direct electrical contact. It is based on the Hall effect, which is ... energy systems, where accurate and non-intrusive current measurement is essential for control and protection purposes....

Show More

What is a microcontroller?
Answer : A microcontroller is a small, integrated circuit (IC) that contains a processor core, memory, and various input/output peripherals, all on a single chip. It is a self- ... an essential component in modern technology, enabling the development of sophisticated and intelligent electronic devices....

Show More

What is a radio-frequency identification (RFID) system?
Answer : A Radio-Frequency Identification (RFID) system is a technology that uses radio waves to wirelessly identify and track objects or individuals. It consists of two main components: RFID tags ... . To address these concerns, appropriate security measures must be implemented when deploying RFID systems....

Show More

What is a Taylor series approximation in circuit analysis?
Answer : In circuit analysis, a Taylor series approximation is a mathematical technique used to simplify the behavior of a nonlinear circuit element or function around a specific operating point. It is ... , such as numerical simulation or iterative techniques, might be required for precise circuit analysis....

Show More

What is a pi (π) filter?
Answer : A Pi (π) filter is a type of electronic filter used in electrical engineering and electronics to attenuate or block certain frequencies of signals while allowing others to pass through. It is ... , load requirements, and the specific application's needs to ensure the filter operates as intended....

Show More

What is a time-domain reflectometer (TDR)?
Answer : A Time-Domain Reflectometer (TDR) is a specialized electronic instrument used to analyze and measure the characteristics of transmission lines, cables, and other electrical components in the time ... , and many other industries where precise analysis of transmission lines and cables is essential....

Show More

What is a digitally controlled oscillator (DCO)?
Answer : A Digitally Controlled Oscillator (DCO) is an electronic oscillator that generates an output signal, typically a periodic waveform such as a sine wave, square wave, or triangle ... , and synchronization, making DCOs essential components in modern electronic devices and communication systems....

Show More

What is a Schottky barrier diode (SBD)?
Answer : A Schottky Barrier Diode (SBD), also known as a Schottky diode or hot carrier diode, is a semiconductor device that functions as a rectifier. It is named after the German physicist ... blocking of reverse current, as their reverse leakage current can be relatively higher than conventional diodes....

Show More

What is an electronic oscillator's phase noise?
Answer : Phase noise is a phenomenon that affects electronic oscillators, such as those used in radio frequency (RF) communication systems, radar systems, and various other electronic devices. An ... specific requirements for phase noise depend on the application and the system's performance goals....

Show More

What is a dynamic RAM (DRAM)?
Answer : Dynamic RAM, commonly known as DRAM, is a type of random-access memory used in computers and other electronic devices. It is the most common form of RAM found in modern systems ... higher performance and increased memory density, catering to the demands of ever-advancing technology and applications....

Show More

What is a superheterodyne receiver?
Answer : A superheterodyne receiver is a type of radio receiver used to amplify and demodulate radio frequency (RF) signals, converting them into audio or digital signals. It is one of the most ... receiver designs. This makes it a fundamental and widely used concept in radio and communication systems....

Show More

What is a Wien bridge oscillator with amplitude control?
Answer : A Wien bridge oscillator is a type of electronic oscillator circuit that generates sinusoidal waves at a specific frequency. It is named after its inventor, Max Wien. The basic Wien bridge ... systems, where the ability to adjust the signal amplitude is important to meet specific requirements....

Show More
Welcome to Learn Electrical, where you can Learn Electrical and Electronics Engineering from Basics to Advanced Level by Questions, Answers and Videos.
...