🔍
What is Ohm's Law?

1 Answer

Ohm's Law is a fundamental principle in electrical engineering and physics that describes the relationship between voltage, current, and resistance in an electrical circuit. It is named after the German physicist Georg Simon Ohm, who formulated it in the 1820s.

Ohm's Law is mathematically expressed as:

V = I * R

Where:

V is the voltage across the circuit (measured in volts, V).
I is the current flowing through the circuit (measured in amperes, A).
R is the resistance of the circuit (measured in ohms, Ω).

According to Ohm's Law, the voltage across a circuit is directly proportional to the current passing through it, and this relationship is inversely proportional to the resistance of the circuit. In other words:

If the voltage (V) increases while the resistance (R) remains constant, the current (I) will increase.
If the resistance (R) increases while the voltage (V) remains constant, the current (I) will decrease.

Ohm's Law is particularly useful in analyzing and designing electrical circuits, as it helps engineers and scientists understand how voltage, current, and resistance interact with each other. This law forms the foundation for many electrical applications and calculations.
0 like 0 dislike

Related questions

What is the relationship between voltage and magnetic domains in a circuit based on Ohm's Law?
Answer : Ohm's Law primarily relates to the relationship between voltage, current, and resistance in an electric circuit. It states that the current passing through a conductor between two points is ... domains is related to the magnetic effects induced by current flow in electromagnets and transformers....

Show More

What is the relationship between voltage and magnetic domains in a circuit based on Ohm's Law?
Answer : Ohm's Law relates voltage, current, and resistance in an electrical circuit and does not directly involve magnetic domains. However, the presence of magnetic domains and the behavior of ... magnetic fields is crucial in designing and analyzing circuits that involve inductors and magnetic components....

Show More

What is the relationship between voltage and magnetic domains in a circuit based on Ohm's Law?
Answer : Ohm's Law describes the relationship between voltage, current, and resistance in an electrical circuit. It states that the current flowing through a conductor between two points is directly ... with the relationship between voltage, current, and resistance in a simple resistive electrical circuit....

Show More

What is the relationship between voltage and magnetic domains in a circuit based on Ohm's Law?
Answer : Ohm's Law primarily relates to the relationship between voltage, current, and resistance in an electric circuit. It does not directly involve magnetic domains, which are related to the behavior ... described by Ohm's Law. Instead, it involves principles from electromagnetism and magnetic materials....

Show More

What is the relationship between voltage and magnetic coercivity in a circuit based on Ohm's Law?
Answer : Ohm's Law describes the relationship between voltage, current, and resistance in an electrical circuit. It states that the current passing through a conductor between two points is directly ... such as those from magnetism and magnetic materials, are used to explain and study coercivity....

Show More

What is the relationship between voltage and magnetic remanence in a circuit based on Ohm's Law?
Answer : Ohm's Law is primarily concerned with the relationship between voltage, current, and resistance in an electrical circuit. It states that the current flowing through a conductor between ... of components in a circuit is described by electromagnetic principles and specific magnetic properties....

Show More

What is the relationship between voltage and magnetic hysteresis in a circuit based on Ohm's Law?
Answer : Ohm's Law relates the voltage, current, and resistance in an electrical circuit. It states that the current flowing through a conductor between two points is directly proportional to the ... and magnetic principles (such as magnetic hysteresis) to understand the complete behavior of the system....

Show More

What is the relationship between voltage and magnetic saturation in a circuit based on Ohm's Law?
Answer : Ohm's Law relates voltage, current, and resistance in a circuit and is given by the equation V = I * R, where V is the voltage, I is the current, and R is the ... of the magnetic circuit determine how magnetic saturation behaves in response to the applied voltage or magnetic field strength....

Show More

What is the relationship between voltage and magnetic reluctance in a circuit based on Ohm's Law?
Answer : In a circuit, Ohm's Law relates voltage, current, and resistance. It states that the voltage (V) across a resistor (or any resistive element) is directly proportional to the current (I) flowing ... Φ) multiplied by magnetic reluctance (Θ) in a magnetic circuit (Ampere's Law for Magnetic Circuits)....

Show More

What is the relationship between voltage and magnetic permeability in a circuit based on Ohm's Law?
Answer : Ohm's Law relates the voltage, current, and resistance in an electrical circuit. It states that the current passing through a conductor between two points is directly proportional to ... components within a circuit, leading to changes in effective resistance and other electrical characteristics....

Show More

What is the relationship between voltage and reactance in a circuit based on Ohm's Law?
Answer : Ohm's Law relates voltage, current, and resistance in a circuit. It states that the voltage (V) across a component in an electrical circuit is directly proportional to the current (I) flowing ... and Ohm's Law can be extended to include reactance in the calculation of voltage across these elements....

Show More

What is the relationship between voltage and mutual inductance in a circuit based on Ohm's Law?
Answer : Ohm's Law relates voltage, current, and resistance in a circuit and can be expressed as: V = I * R Where: V is the voltage across the circuit (measured in volts, V), I is the ... which relates the induced voltage to the mutual inductance and the rate of change of current in the nearby circuit....

Show More

What is the relationship between voltage and impedance in a circuit based on Ohm's Law?
Answer : In a circuit, Ohm's Law establishes a relationship between voltage, current, and impedance (or resistance). The formula for Ohm's Law is: V = I * Z Where: V is the voltage ... impedance or resistance changes, the voltage across the circuit will also change proportionally to the new current flow....

Show More

What is the relationship between voltage and inductance in a circuit based on Ohm's Law?
Answer : Ohm's Law describes the relationship between voltage, current, and resistance in an electrical circuit. However, when it comes to inductance, Ohm's Law alone is not sufficient. Instead, we need ... reactance, which is part of the impedance formula for an inductor in an alternating current circuit....

Show More

What is the relationship between voltage and capacitance in a circuit based on Ohm's Law?
Answer : Ohm's Law describes the relationship between voltage (V), current (I), and resistance (R) in an electrical circuit and is represented by the equation: V = I * R However, ... crucial in understanding the behavior of capacitors in circuits and their ability to store and release electrical energy....

Show More

What is the relationship between power dissipation and resistance in a circuit according to Ohm's Law?
Answer : According to Ohm's Law, the relationship between power dissipation, resistance, and current in an electrical circuit is described by the formula: = 2 P=I 2 R Where: P ... Law is a fundamental principle in electrical engineering and is widely used to analyze and design electrical circuits....

Show More

What is the relationship between voltage and resistance in a circuit based on Ohm's Law?
Answer : Ohm's Law describes the relationship between voltage (V), current (I), and resistance (R) in an electrical circuit. It states that the voltage across a resistor is directly proportional ... given the voltage and resistance or determine the required resistance for a specific current and voltage....

Show More

What is the relationship between resistance and temperature in a circuit according to Ohm's Law?
Answer : According to Ohm's Law, the relationship between resistance and temperature in a circuit is not directly stated in the law itself. Ohm's Law primarily deals with the relationship ... resistive materials in a circuit, especially when dealing with thermistors or other temperature-sensitive components....

Show More

What is the relationship between voltage and power in a circuit based on Ohm's Law?
Answer : Ohm's Law describes the relationship between voltage (V), current (I), and resistance (R) in an electrical circuit. It is expressed mathematically as: V = I * R where: V = Voltage ( ... of voltage and current, you can use these formulas to calculate the power consumed or dissipated by the circuit....

Show More

What is the relationship between current and charge in a circuit based on Ohm's Law?
Answer : Ohm's Law defines the relationship between current, voltage, and resistance in an electrical circuit. It states that the current (I) flowing through a conductor is directly proportional to the voltage ... and resistance are known or in finding the voltage or resistance when the current is known....

Show More

What is the relationship between voltage, current, and power in a circuit according to Ohm's Law?
Answer : Ohm's Law is a fundamental principle in electrical circuits that describes the relationship between voltage, current, and resistance. It states that the current (I) flowing through a conductor ... decrease. Hence, understanding Ohm's Law is crucial in analyzing and designing electrical circuits....

Show More

What is the significance of Ohm's Law in designing power supplies?
Answer : Ohm's Law is a fundamental principle in electrical engineering and plays a crucial role in designing power supplies. It describes the relationship between voltage, current, and resistance in an ... safe, efficient, and reliable power solutions for a wide range of electronic devices and systems....

Show More

What is the phase relationship between voltage and current in capacitive and inductive circuits according to Ohm's Law?
Answer : According to Ohm's Law, the phase relationship between voltage and current in capacitive and inductive circuits is different from that in purely resistive circuits. Ohm's Law states that the ... and inductors in AC circuits and is an important concept in electrical engineering and electronics....

Show More

What is the difference between active and passive components concerning Ohm's Law?
Answer : Ohm's Law, named after the German physicist Georg Simon Ohm, relates the voltage (V), current (I), and resistance (R) in an electrical circuit. The law is represented ... complex, may have varying relationships between voltage and current depending on their specific characteristics and functions....

Show More

What is the role of Ohm's Law in determining the power ratings of electrical components?
Answer : Ohm's Law plays a crucial role in determining the power ratings of electrical components. Ohm's Law relates voltage (V), current (I), and resistance (R) in an electrical ... provide a fundamental basis for understanding and determining the power ratings of electrical components in various circuits....

Show More

What is the difference between series and parallel circuits in terms of voltage and current according to Ohm's Law?
Answer : Ohm's Law is a fundamental principle in electrical circuits that relates voltage, current, and resistance. It states that the current (I) flowing through a conductor between two points is directly ... across all components, and the total current is the sum of the currents in each branch....

Show More

What is a linear circuit? How does it relate to Ohm's Law?
Answer : A linear circuit is an electrical circuit in which the components and their interconnections follow linear relationships between voltage, current, and impedance. In simpler terms, the response of a ... , making them simpler to analyze and predict their behavior compared to non-linear circuits....

Show More

What happens to the current if the voltage is zero in Ohm's Law?
Answer : According to Ohm's Law, the relationship between voltage (V), current (I), and resistance (R) in a circuit is given by the formula: V = I * R If the voltage (V) is zero, ... , the current would become infinitely large, leading to a short circuit scenario, which is generally not desirable or safe....

Show More

What is the significance of Ohm's Law in electrical engineering?
Answer : Ohm's Law is one of the fundamental principles in electrical engineering and plays a crucial role in understanding and analyzing electrical circuits. It was formulated by the German ... anyone working with electrical circuits to have a solid understanding of its principles and applications....

Show More

How is Ohm's Law used in determining the current through an inductor in a transient response?
Answer : Ohm's Law is not directly applicable to determining the current through an inductor in a transient response. Ohm's Law is a fundamental principle in electrical circuits that relates voltage (V), ... current through the inductor as the circuit reaches a stable state after a sudden change in voltage....

Show More

How is Ohm's Law used in determining the current through an inductor in an AC circuit?
Answer : Ohm's Law is not directly applicable to determining the current through an inductor in an AC (alternating current) circuit because inductors exhibit different behavior than resistors when AC voltage is applied. ... in an inductor lags the voltage by 90 degrees in an ideal inductor in an AC circuit....

Show More

How is Ohm's Law used in determining the current through a transistor in cutoff region?
Answer : Ohm's Law is not directly applicable to determine the current through a transistor in cutoff region, as Ohm's Law primarily deals with the relationship between voltage, current, and resistance in ... , the collector current is negligible, and the transistor is effectively acting as an open circuit....

Show More

How is Ohm's Law used in determining the current through a transistor in active region?
Answer : Ohm's Law is an essential principle in electronics that relates voltage, current, and resistance in a circuit. In the context of determining the current through a transistor in its active region, ... described by more complex models and equations specific to each type of transistor (BJT or MOSFET)....

Show More

How is Ohm's Law used in determining the current through a zener diode in forward bias?
Answer : Ohm's Law is not directly applicable to determining the current through a zener diode in forward bias. Ohm's Law relates the voltage across a resistor to the current passing through it, and ... s forward voltage and current characteristics as provided in the datasheet, rather than using Ohm's Law....

Show More

How is Ohm's Law used in determining the current through a zener diode in reverse bias?
Answer : Ohm's Law is a fundamental principle in electronics that relates the voltage, current, and resistance of a circuit. It is commonly used to determine the current through a zener diode ... is crucial for designing and analyzing zener diode circuits used in voltage regulation and other applications....

Show More

How is Ohm's Law used in determining the current through a diode in breakdown region?
Answer : Ohm's Law is not directly applicable to determine the current through a diode in the breakdown region because diodes do not obey Ohm's Law in this specific operating region. Ohm's Law ... diode's characteristic curves or specific models to understand its behavior in this non-linear operating region....

Show More

How is Ohm's Law used in determining the current through a diode in forward bias?
Answer : Ohm's Law is not directly applicable to determining the current through a diode in forward bias. Ohm's Law, which states that the current (I) flowing through a conductor between two points is ... diode equation or other more specific diode models are used to analyze diode behavior in forward bias....

Show More

How is Ohm's Law used in determining the current through a transistor in cutoff region?
Answer : In the cutoff region of a transistor, the transistor is essentially turned off, and only a negligible current flows between its collector and emitter terminals. Ohm's Law is not directly applicable ... -emitter junction, and the collector current is nearly zero when the transistor is in this mode....

Show More

How is Ohm's Law used in determining the current through a transistor in active region?
Answer : Ohm's Law is not directly used to determine the current through a transistor in the active region. However, it is an important principle that underlies the operation of transistors and ... current, which plays a significant role in controlling the transistor's operation in amplification circuits....

Show More

How is Ohm's Law used in determining the current through a diode in reverse bias?
Answer : Ohm's Law is not directly applicable to determining the current through a diode in reverse bias because diodes do not obey Ohm's Law under reverse bias conditions. Ohm's Law ... consider this parameter in their circuit calculations to ensure proper functionality and avoid any unexpected behavior....

Show More

How is Ohm's Law used in determining the current through a transistor in saturation mode?
Answer : Ohm's Law is a fundamental principle in electronics that relates voltage, current, and resistance in a circuit. In the context of determining the current through a transistor in saturation mode, Ohm ... , Ohm's Law plays a crucial role in understanding the behavior of transistors in saturation mode....

Show More

How is Ohm's Law used in determining the current through a resistor in an AC circuit?
Answer : Ohm's Law is a fundamental principle in electrical engineering and is commonly used to determine the current through a resistor in an AC (alternating current) circuit, just as it is used in DC ... current that would produce the same heating effect in the resistor as the AC current over time....

Show More

How is Ohm's Law used in determining the current through a zener diode in a voltage regulator?
Answer : Ohm's Law is a fundamental principle in electrical engineering that relates voltage, current, and resistance in a circuit. It is commonly used in various electronic applications, including determining ... zener diode with a breakdown voltage close to the desired output voltage for better regulation....

Show More

How is Ohm's Law used in determining the current through a fuse during overload situations?
Answer : Ohm's Law is a fundamental principle in electrical engineering that describes the relationship between voltage, current, and resistance in a circuit. It can be used to determine the current through ... the fuse's rated current, the fuse will break the circuit, providing protection against overloads....

Show More

How is Ohm's Law used in determining the current in a short-circuit situation?
Answer : Ohm's Law is a fundamental principle in electrical engineering and is used extensively to determine various electrical parameters, including current, voltage, and resistance in a circuit. In a ... are crucial to prevent excessive current and protect the circuit from damage and potential hazards....

Show More

How is Ohm's Law used in determining the voltage drop across diodes in forward bias?
Answer : Ohm's Law is not directly used to determine the voltage drop across diodes in forward bias. Instead, Ohm's Law is typically applied to calculate the current flowing through the diode ... . More accurate models and specifications can be found in the datasheets provided by diode manufacturers....

Show More

How is Ohm's Law used in designing electronic timers and time-delay circuits?
Answer : Ohm's Law is a fundamental principle in electronics that relates the voltage, current, and resistance of an electrical circuit. It is commonly used in designing electronic timers and time-delay ... effects, and power ratings should be taken into account for reliable and accurate timer designs....

Show More

How is Ohm's Law used in designing electronic oscillators?
Answer : Ohm's Law is a fundamental principle in electronics that relates voltage, current, and resistance in an electrical circuit. It is often used in designing electronic oscillators, which are ... the circuit and ensuring the oscillator operates as intended with the desired frequency and stability....

Show More

How is Ohm's Law used in designing electronic switches and relays?
Answer : Ohm's Law is a fundamental principle in electronics that describes the relationship between voltage, current, and resistance in a circuit. It is commonly used in designing electronic switches ... current-carrying capacity, ensuring the reliable and robust operation of the final electronic devices....

Show More

How is Ohm's Law used in designing electronic filters?
Answer : Ohm's Law is a fundamental principle in electronics that relates voltage, current, and resistance in a circuit. It can be applied to design electronic filters, particularly when working ... additional equations and considerations, but Ohm's Law remains a fundamental principle throughout the process....

Show More
Welcome to Learn Electrical, where you can Learn Electrical and Electronics Engineering from Basics to Advanced Level by Questions, Answers and Videos.
...