🔍
A.C. Fundamentals - Admittance (Y)

1 Answer

Admittance (Y) is a fundamental concept in the field of electrical engineering and A.C. (alternating current) circuit analysis. It is the reciprocal of impedance (Z) and is used to describe the ease with which alternating current flows through an electrical circuit.

The admittance (Y) of an electrical element or a circuit is given by the formula:


=
1

Y=
Z
1
    ​


where:


Y represents the admittance in siemens (S)

Z represents the impedance in ohms (
Ω
Ω)

Impedance (

Z) combines both resistance (

R) and reactance (

X) in a complex manner and is a measure of opposition to the flow of alternating current in a circuit. It can be expressed in rectangular form as:


=

+


Z=R+jX

where:


R is the resistance in ohms (
Ω
Ω)

j is the imaginary unit (

=

1
j=
−1
    ​

)

X is the reactance in ohms (
Ω
Ω)

Reactance can be inductive (


X
L
    ​

) or capacitive (


X
C
    ​

), depending on the nature of the circuit element. Inductive reactance is associated with coils and transformers, while capacitive reactance is associated with capacitors.

The admittance can also be expressed in rectangular form, similar to impedance:


=

+


Y=G+jB

where:


G is the conductance in siemens (S)

j is the imaginary unit (

=

1
j=
−1
    ​

)

B is the susceptance in siemens (S)

Just as resistance is a measure of how easily direct current flows through a circuit, conductance (

G) is a measure of how easily alternating current flows through a circuit. Susceptance (

B) is the analog of reactance for admittance and represents the ability of a circuit to store or release energy.

In summary, admittance (

Y) is the reciprocal of impedance (

Z) and is used to quantify how easily alternating current flows through a circuit. It takes into account both conductance (

G) and susceptance (

B) components, which are analogous to resistance and reactance, respectively, in impedance. Admittance is a crucial concept in AC circuit analysis, especially when dealing with complex circuits containing multiple elements with varying conductance and susceptance values.
0 like 0 dislike

Related questions

A.C. Fundamentals - Admittance (Y) in R-L series circuit
Answer : In an A.C. (alternating current) electrical circuit, admittance (Y) is a measure of how easily current flows through the circuit. It is the reciprocal of impedance (Z) and is analogous to ... the frequency of the AC signal and the values of resistance, inductance, and capacitance in the circuit....

Show More

A.C. Fundamentals - Importance of Admittance in Parallel A.C. Circuit Analysis
Answer : Admittance is a crucial concept in the analysis of parallel AC (alternating current) circuits. In AC circuit analysis, we often deal with complex quantities that involve both magnitude ... circuits. Admittance helps engineers and students work with parallel AC circuits efficiently and effectively....

Show More

A.C. Fundamentals - Components of admittance
Answer : In the context of electrical circuits and alternating current (AC) fundamentals, admittance is the reciprocal of impedance. It's a complex quantity that encompasses both the conductance and susceptance of ... provides insight into the ease of current flow and the reactive nature of the circuit....

Show More

A.C. Fundamentals - Application of Admittance Method
Answer : The admittance method is a technique used in AC (alternating current) circuit analysis to solve circuits in terms of admittances, which are the reciprocals of impedances. Admittance is a complex ... every circuit, but it provides an alternative perspective that can be helpful in certain scenarios....

Show More

A.C. Fundamentals - Admittance Triangle
Answer : The Admittance Triangle is a graphical representation used in alternating current (AC) circuit analysis to understand the relationships between impedance, admittance, and phase angle. It is ... tool for analyzing AC circuits, especially when dealing with complex impedances and phase differences....

Show More

A.C. Fundamentals - Admittance Method for Parallel A.C. Circuit Solution
Answer : The Admittance Method is a technique used to analyze parallel AC circuits. Admittance (Y) is the reciprocal of impedance (Z), and it is a complex quantity that includes both magnitude ... circuits by using admittances, which are easier to manipulate in algebraic calculations compared to impedances....

Show More

A.C. Fundamentals - Y-Parameter
Answer : Y-parameters, also known as admittance parameters or hybrid parameters, are a set of parameters used to describe the behavior of a linear two-port network. Y-parameters are particularly useful ... specific use and interpretation might vary based on the context and type of circuit being analyzed....

Show More

A.C. Fundamentals - Voltages, Currents, and Power in Y Connection
Answer : In electrical engineering, AC (alternating current) fundamentals play a crucial role in understanding the behavior of AC circuits. One common configuration is the Y connection, also known ... essential for analyzing and designing AC circuits, especially in industrial and power distribution systems....

Show More

What is admittance (Y) in network parameters?
Answer : Admittance, denoted by Y, is the reciprocal of impedance. It represents the ease with which current flows through an electrical circuit. Admittance is also a complex quantity measured in siemens (S). ...

Show More

A.C. Fundamentals - Z-parameters
Answer : In electrical engineering, A.C. (alternating current) fundamentals are an essential aspect of understanding how electrical circuits behave when exposed to varying voltages and currents. One way ... of components and networks becomes crucial due to the frequency-dependent behavior of these systems....

Show More

A.C. Fundamentals - Waveform
Answer : Alternating Current (AC) fundamentals are essential concepts in electrical engineering and physics that deal with the behavior of electric currents that periodically change direction. One ... helps engineers design and troubleshoot AC circuits, ensuring optimal performance and functionality....

Show More

A.C. Fundamentals - Voltages, Currents, and Power in Delta Connection
Answer : In electrical engineering, the delta connection (also known as a "mesh" or "3-wire" connection) is one of the configurations used to connect three-phase voltage and current ... -world scenarios, power systems may have various complexities and considerations that could affect the calculations....

Show More

A.C. Fundamentals - Variation of Z and i with Frequency
Answer : In the context of electrical circuits and AC (alternating current) fundamentals, let's discuss the variation of impedance (Z) and current (i) with frequency. Impedance (Z): ... and analysis of AC circuits and is fundamental to various applications in electrical engineering and electronics....

Show More

A.C. Fundamentals - Variation of XL, Xc, R, and Z with Frequency
Answer : In the context of alternating current (AC) circuits, XL, XC, R, and Z are important parameters that describe the behavior of circuit elements in response to varying frequency. Let' ... , as well as for applications in fields such as electronics, electrical engineering, and telecommunications....

Show More

A.C. Fundamentals - Values of Alternating Voltage and Current
Answer : Alternating Current (AC) fundamentals involve understanding the properties and values of alternating voltage and current. AC is the type of electric current that changes direction periodically, as opposed ... as they form the basis for analyzing and designing various electrical systems and devices....

Show More

A.C. Fundamentals - Unit-Step Function
Answer : Certainly, I can help you with that! In the context of A.C. (Alternating Current) Fundamentals, the Unit Step Function is often referred to as the Heaviside step function, or simply the unit ... . If you have specific questions or scenarios in mind, feel free to ask for more detailed explanations!...

Show More

A.C. Fundamentals - Unbalanced Load
Answer : In the context of electrical engineering, A.C. (alternating current) fundamentals refer to the principles and concepts related to alternating current systems. An unbalanced load refers to ... properly design, monitor, and maintain electrical systems to ensure balanced loads and optimal performance....

Show More

A.C. Fundamentals - Two Wattmeter Method
Answer : The Two Wattmeter Method is a technique used for measuring the power in a three-phase AC circuit. It is commonly employed in balanced and unbalanced three-phase systems to determine the ... measurements. It's important to follow safety guidelines when working with electrical circuits and equipment....

Show More

A.C. Fundamentals - True power
Answer : In the context of electrical engineering and AC (alternating current) fundamentals, "true power" refers to the actual power consumed by a circuit or device that is connected to an ... power represents the energy oscillating between the source and reactive components without performing useful work....

Show More

A.C. Fundamentals - Trigonometrical form
Answer : Trigonometric forms, also known as trigonometric representations or polar forms, are alternative ways to express complex numbers. A complex number is a number that comprises a real part and ... as these operations become simpler in trigonometric or exponential forms compared to the rectangular form....

Show More

A.C. Fundamentals - Transient Response in R-L-C Circuit
Answer : A.C. Fundamentals - Transient Response in R-L-C Circuit In the realm of AC (alternating current) circuits, the behavior of circuits with resistors (R), inductors (L), and ... understanding. Detailed calculations, Laplace transforms, and differential equations are often used for in-depth analysis....

Show More

A.C. Fundamentals - Time period and frequency
Answer : In the realm of electrical engineering and physics, alternating current (AC) is a type of electrical current where the direction of the current periodically reverses. Two fundamental ... analyzing AC circuits, including topics like waveform generation, signal processing, and power distribution....

Show More

A.C. Fundamentals - Time period
Answer : In the context of A.C. (alternating current) fundamentals, the term "time period" refers to a fundamental parameter of an AC waveform. Alternating current is characterized by its periodic ... , calculating phase differences, and determining the behavior of AC signals in different types of circuits....

Show More

A.C. Fundamentals - T-section
Answer : T-section, also known as T-network, is a type of electrical circuit configuration often used in electronics and electrical engineering. It is commonly used in filter design and impedance matching ... Pi-sections, L-sections, and more complex networks like Butterworth, Chebyshev, and Bessel filters....

Show More

A.C. Fundamentals - Susceptance-frequency curve
Answer : The Susceptance-frequency curve, also known as the B-f curve, is a graphical representation of how the susceptance (B) of a circuit component or network changes with respect to frequency. ... in a circuit interact and how they affect the overall behavior of the circuit at different frequencies....

Show More

A.C. Fundamentals - Subtraction of Alternating Quantities
Answer : Subtraction of alternating quantities in AC (alternating current) circuits involves applying the same principles as subtraction in DC circuits but taking into account the complex nature of AC voltages ... complex scenarios, such as using phasor diagrams or complex algebra to solve circuit problems....

Show More

A.C. Fundamentals - Step Response of R-L-C Circuit
Answer : The step response of an R-L-C circuit refers to how the circuit's output voltage or current responds when a step input voltage is applied to it. An R-L-C circuit is ... Understanding these parameters and the behavior of the circuit helps in designing and analyzing circuits for various applications....

Show More

A.C. Fundamentals - Step Response of R-L-C Circuit
Answer : The step response of an R-L-C circuit refers to how the circuit behaves when a sudden change, or step, is applied to its input voltage or current. The response is characterized by the ... insights into how the circuit responds to sudden changes and how it eventually settles into a stable state....

Show More

A.C. Fundamentals - Step Response of R-L Circuit
Answer : In electrical engineering, the step response of a circuit is the behavior of the circuit when subjected to a sudden change in input, typically from zero to a constant value (step input). ... in the inductor's windings, or mutual inductance if multiple inductors are present in the circuit....

Show More

A.C. Fundamentals - Step Response of R-C Circuit
Answer : The step response of an R-C (resistor-capacitor) circuit refers to the behavior of the circuit when a sudden change, or step, in input voltage is applied. This behavior is especially ... or discharging of the capacitor, and this behavior is characterized by the time constant of the circuit....

Show More

A.C. Fundamentals - Star Connection
Answer : In electrical engineering, AC (alternating current) fundamentals refer to the basic principles and concepts related to alternating current systems. One important aspect of AC systems is the different ... in scenarios where a neutral point is needed for grounding and maintaining system stability....

Show More

A.C. Fundamentals - Star Connected Load
Answer : In the context of electrical engineering and AC (alternating current) fundamentals, a "Star Connected Load" refers to a specific configuration of three-phase electrical loads. Three-phase AC ... between them depends on the specific requirements of the electrical system and the connected devices....

Show More

A.C. Fundamentals - Some Cases of Parallel Connected Elements
Answer : In the realm of electrical engineering and circuit theory, parallel-connected elements are components that are connected across the same two nodes, sharing the same voltage difference. Here are some ... , so it's important to apply the appropriate formulas and techniques to simplify the analysis....

Show More

A.C. Fundamentals - Sinusoidal Function
Answer : Certainly, I can help you with AC (alternating current) fundamentals and sinusoidal functions. AC Fundamentals: Alternating current (AC) is an electric current that periodically reverses direction. It is ... working with AC electricity, as it forms the basis for AC circuit analysis and design....

Show More

A.C. Fundamentals - Sinusoidal Alternating Voltage and Current
Answer : Certainly, I'd be happy to explain the basics of sinusoidal alternating voltage and current, which are fundamental concepts in the study of electrical circuits and systems. Sinusoidal Alternating ... designing and analyzing electrical circuits, as well as for working with electrical power systems....

Show More

A.C. Fundamentals - Sine Waveform
Answer : Alternating Current (AC) fundamentals are essential concepts in electrical engineering, and one of the fundamental AC waveforms is the sine wave. A sine wave is a smooth, periodic ... analyzing and designing AC circuits, working with electrical systems, and various other engineering applications....

Show More

A.C. Fundamentals - Significance of Power Factor
Answer : Power factor is a critical concept in AC (alternating current) electrical systems and plays a significant role in the efficient and reliable operation of various electrical devices and systems. ... efforts to improve power factor can result in substantial benefits for both consumers and utilities....

Show More

A.C. Fundamentals - Significance of Operator j
Answer : In electrical engineering and physics, the operator "j" is commonly used to represent the imaginary unit, which is equal to the square root of -1. In other fields of mathematics and ... numbers and phasor notation, facilitating the analysis, design, and operation of AC circuits and systems....

Show More

A.C. Fundamentals - Sharpness of Resonance
Answer : In the context of A.C. (alternating current) fundamentals, "sharpness of resonance" refers to the degree to which a resonant circuit or system can amplify a specific frequency of ... . The sharpness of resonance allows for precise frequency selection and filtering in various electronic systems....

Show More

A.C. Fundamentals - Series-to-Parallel Conversion and Vice-Versa
Answer : Converting electrical circuits from series to parallel or vice-versa is a common task in electrical engineering. Series and parallel circuits have distinct properties, and the conversion ... and circuit configurations to ensure they meet the desired electrical specifications and requirements....

Show More

A.C. Fundamentals - Series-Parallel A.C. Circuits
Answer : A.C. (alternating current) fundamentals play a crucial role in understanding electrical circuits, both in series and parallel configurations. Let's delve into series-parallel A.C. ... relationships between currents, voltages, impedances, and phasors to effectively analyze and design circuits....

Show More

A.C. Fundamentals - Series Resonance
Answer : Certainly, I can help you understand series resonance in A.C. (alternating current) circuits! Series resonance is a phenomenon that occurs in circuits that consist of a resistor (R), ... -world scenarios, components have tolerances and parasitic effects that can affect the behavior of the circuit....

Show More

A.C. Fundamentals - Series R-L-C Circuit
Answer : A.C. fundamentals refer to the principles and concepts related to alternating current (A.C.) circuits. A series R-L-C circuit is a type of A.C. circuit that consists of a resistor ( ... , where A.C. circuits are commonly used in applications like filters, tuning circuits, and impedance matching....

Show More

A.C. Fundamentals - Series R-C Circuit
Answer : A series R-C circuit is an electrical circuit that consists of a resistor (R) and a capacitor (C) connected in series to a voltage source (generally an AC voltage source). ... , makes this circuit configuration valuable for applications like filtering high-frequency noise and generating time delays....

Show More

A.C. Fundamentals - Root Mean Square (R.M.S.) Value of Alternating Current
Answer : In alternating current (AC) circuits, the Root Mean Square (RMS) value is a crucial parameter that helps us understand the equivalent steady DC value of an AC waveform. It's a way to ... AC quantities are consistent with their DC equivalents, making analysis and design of AC systems more manageable....

Show More

A.C. Fundamentals - Resonance in Parallel A.C. Circuits (Parallel Resonance)
Answer : Parallel resonance, also known as anti-resonance, is a phenomenon that occurs in parallel AC circuits when the impedance of the circuit is minimized and the current flowing through the ... of electronics and electrical engineering, as it provides insights into circuit behavior and performance....

Show More

A.C. Fundamentals - Resonance in A.C. Circuits
Answer : Resonance in AC circuits is a phenomenon that occurs when the inductive reactance (XL) and capacitive reactance (XC) in a circuit become equal, resulting in a condition where the ... and capacitors. It allows engineers to optimize circuit performance for specific frequency ranges and applications....

Show More

A.C. Fundamentals - Resonance Curve
Answer : Sure, I'd be happy to explain A.C. fundamentals and the resonance curve. A.C. Fundamentals: Alternating Current (A.C.) is an electric current that reverses direction ... response amplitude in circuits with reactive components, showing the phenomenon of resonance at the resonant frequency....

Show More

A.C. Fundamentals - Resonance between Parallel R-L and R-C Circuit
Answer : Resonance is an important concept in AC (alternating current) circuits, particularly when dealing with parallel R-L (resistor-inductor) and R-C (resistor-capacitor) circuits. Resonance occurs when the ... real impedance. This leads to a peak in current and/or voltage at the resonant frequency....

Show More

A.C. Fundamentals - Resistance Element
Answer : In the context of electrical engineering and circuits, the term "A.C. fundamentals" typically refers to the basics of alternating current (A.C.) circuits. One important component of A.C. circuits is ... circuits, whether they are based on direct current (D.C.) or alternating current (A.C.)....

Show More
...