A.C. Fundamentals - Admittance Method for Parallel A.C. Circuit Solution

1 Answer

The Admittance Method is a technique used to analyze parallel AC circuits. Admittance (Y) is the reciprocal of impedance (Z), and it is a complex quantity that includes both magnitude and phase information. Just like impedance, admittance is used to describe how a circuit responds to AC signals.

To solve a parallel AC circuit using the Admittance Method, follow these steps:

Identify the Components: Determine the components in the parallel AC circuit. These could include resistors (R), capacitors (C), and inductors (L).

Convert Components to Admittance: Convert each component's impedance to its corresponding admittance. Use the following formulas:

For a resistor:


=
1

Y
R
    ​

=
R
1
    ​

For a capacitor:


=



Y
C
    ​

=jωC
For an inductor:


=
1



Y
L
    ​

=
jωL
1
    ​


Where

j is the imaginary unit,

ω is the angular frequency (equal to
2

2π times the frequency),

C is the capacitance, and

L is the inductance.

Write Kirchhoff's Current Law (KCL): Write down the KCL equation for the parallel circuit. The sum of all currents entering a node must be zero.

Express Currents in Terms of Admittances: Replace the currents in the KCL equation with the corresponding admittances. This will give you an equation in terms of admittances.

Solve for Total Admittance: Sum up all the admittances to find the total admittance (

total
Y
total
    ​

) of the parallel circuit.

Find Total Impedance: Take the reciprocal of the total admittance to find the total impedance (

total
Z
total
    ​

) of the circuit:

total
=
1

total
Z
total
    ​

=
Y
total
    ​

1
    ​

.

Find Total Current: If a voltage source is connected to the circuit, use Ohm's Law (

=


total
I=
Z
total
    ​

V
    ​

) to find the total current (

I) flowing through the circuit.

Calculate Branch Currents: Use the total current and the individual admittances to calculate the currents through each branch of the parallel circuit.

Find Voltages and Phasors: Calculate the voltage across each component using Ohm's Law or the appropriate impedance/admittance relationship. These voltages will be complex quantities with both magnitude and phase.

Verify KCL and KVL: Check that Kirchhoff's Current Law and Kirchhoff's Voltage Law are satisfied in the circuit. The sum of the currents at any node should be zero, and the sum of the voltages around any closed loop should be zero.

Remember that when working with complex quantities, it's important to consider both the magnitude and phase of voltages, currents, and impedances/admittances. You can represent these quantities in either rectangular (Cartesian) or polar (phasor) form.

The Admittance Method simplifies the analysis of parallel AC circuits by using admittances, which are easier to manipulate in algebraic calculations compared to impedances.
0 like 0 dislike

Related questions

A.C. Fundamentals - Importance of Admittance in Parallel A.C. Circuit Analysis
Answer : Admittance is a crucial concept in the analysis of parallel AC (alternating current) circuits. In AC circuit analysis, we often deal with complex quantities that involve both magnitude ... circuits. Admittance helps engineers and students work with parallel AC circuits efficiently and effectively....

Show More

A.C. Fundamentals - Application of Admittance Method
Answer : The admittance method is a technique used in AC (alternating current) circuit analysis to solve circuits in terms of admittances, which are the reciprocals of impedances. Admittance is a complex ... every circuit, but it provides an alternative perspective that can be helpful in certain scenarios....

Show More

A.C. Fundamentals - Admittance (Y) in R-L series circuit
Answer : In an A.C. (alternating current) electrical circuit, admittance (Y) is a measure of how easily current flows through the circuit. It is the reciprocal of impedance (Z) and is analogous to ... the frequency of the AC signal and the values of resistance, inductance, and capacitance in the circuit....

Show More

A.C. Fundamentals - Components of admittance
Answer : In the context of electrical circuits and alternating current (AC) fundamentals, admittance is the reciprocal of impedance. It's a complex quantity that encompasses both the conductance and susceptance of ... provides insight into the ease of current flow and the reactive nature of the circuit....

Show More

A.C. Fundamentals - Admittance Triangle
Answer : The Admittance Triangle is a graphical representation used in alternating current (AC) circuit analysis to understand the relationships between impedance, admittance, and phase angle. It is ... tool for analyzing AC circuits, especially when dealing with complex impedances and phase differences....

Show More

A.C. Fundamentals - Admittance (Y)
Answer : Admittance (Y) is a fundamental concept in the field of electrical engineering and A.C. (alternating current) circuit analysis. It is the reciprocal of impedance (Z) and ... especially when dealing with complex circuits containing multiple elements with varying conductance and susceptance values....

Show More

A.C. Fundamentals - Resonance between Parallel R-L and R-C Circuit
Answer : Resonance is an important concept in AC (alternating current) circuits, particularly when dealing with parallel R-L (resistor-inductor) and R-C (resistor-capacitor) circuits. Resonance occurs when the ... real impedance. This leads to a peak in current and/or voltage at the resonant frequency....

Show More

A.C. Fundamentals - Q-factor of a Parallel Resonant Circuit
Answer : The Q-factor (Quality Factor) of a parallel resonant circuit, also known as a parallel RLC circuit, is a measure of its efficiency and selectivity. It indicates how well the circuit can ... store energy at the resonant frequency and attenuate frequencies that are not close to the resonant frequency....

Show More

A.C. Fundamentals - Parallel R-L-C Circuit
Answer : A parallel R-L-C circuit is an electrical circuit that contains resistive (R), inductive (L), and capacitive (C) components connected in parallel. In this configuration, the components ... inductance of connecting wires and parasitic elements that might need to be considered for accurate analysis....

Show More

A.C. Fundamentals - Parallel R-L-C Circuit
Answer : A parallel R-L-C circuit is an electrical circuit that consists of resistors (R), inductors (L), and capacitors (C) connected in parallel. In this configuration, the components ... phasor diagrams to understand the relationships between voltage, current, and phase angles across the components....

Show More

A.C. Fundamentals - Parallel R-L Circuit
Answer : A parallel R-L circuit is an electrical circuit that consists of resistive (R) and inductive (L) components connected in parallel. In this type of circuit, the components share the same ... , phase angle, and time constants, which influence the circuit's response to alternating current signals....

Show More

A.C. Fundamentals - Parallel R-C Circuit
Answer : An R-C circuit (resistor-capacitor circuit) is a combination of passive electrical components-an resistor (R) and a capacitor (C)-connected together in a specific configuration. ... electronics and electrical engineering applications, particularly in filters, signal processing, and timing circuits....

Show More

A.C. Fundamentals - Comparison of series and parallel resonant circuit
Answer : Series and parallel resonant circuits are two common types of circuits used in electronics and electrical engineering for various applications. They both involve the concept of resonance, which ... between series and parallel resonant circuits depends on the specific requirements of the application....

Show More

A.C. Fundamentals - Bandwidth of Parallel Resonant Circuit
Answer : In A.C. (alternating current) fundamentals, a parallel resonant circuit is a type of electrical circuit that consists of a resistor (R), an inductor (L), and a capacitor (C) connected in ... quality factor leads to a narrower bandwidth, while a lower quality factor results in a wider bandwidth....

Show More

A.C. Fundamentals - General Case for Parallel Resonance
Answer : In the field of electrical engineering, parallel resonance is a phenomenon that occurs in electrical circuits when the reactance of the inductor (XL) and the reactance of the capacitor (XC) cancel ... power systems, such as in the design of filters, tuning circuits, and impedance matching networks....

Show More

A.C. Fundamentals - Two Wattmeter Method
Answer : The Two Wattmeter Method is a technique used for measuring the power in a three-phase AC circuit. It is commonly employed in balanced and unbalanced three-phase systems to determine the ... measurements. It's important to follow safety guidelines when working with electrical circuits and equipment....

Show More

A.C. Fundamentals - Parallelogram method
Answer : The Parallelogram Method is a graphical technique used to analyze and solve problems related to alternating current (AC) circuit fundamentals. It is particularly useful for understanding and ... , especially for gaining an intuitive understanding of the relationships between different AC quantities....

Show More

A.C. Fundamentals - Method of Components
Answer : The term "A.C. Fundamentals" refers to the basic principles and concepts related to alternating current (A.C.) electrical systems. A.C. is the type of electric current where the direction ... and circuit analysis techniques is essential to effectively apply the Method of Components to A.C. circuits....

Show More

A.C. Fundamentals - Equivalent Impedance Method
Answer : The Equivalent Impedance Method is a technique used in the analysis of electrical circuits involving alternating current (AC) sources and components. It simplifies complex networks of impedances into a ... and more advanced techniques like phasor analysis may be needed to fully analyze AC circuits....

Show More

A.C. Fundamentals - Some Cases of Parallel Connected Elements
Answer : In the realm of electrical engineering and circuit theory, parallel-connected elements are components that are connected across the same two nodes, sharing the same voltage difference. Here are some ... , so it's important to apply the appropriate formulas and techniques to simplify the analysis....

Show More

A.C. Fundamentals - Series-to-Parallel Conversion and Vice-Versa
Answer : Converting electrical circuits from series to parallel or vice-versa is a common task in electrical engineering. Series and parallel circuits have distinct properties, and the conversion ... and circuit configurations to ensure they meet the desired electrical specifications and requirements....

Show More

A.C. Fundamentals - Series-Parallel A.C. Circuits
Answer : A.C. (alternating current) fundamentals play a crucial role in understanding electrical circuits, both in series and parallel configurations. Let's delve into series-parallel A.C. ... relationships between currents, voltages, impedances, and phasors to effectively analyze and design circuits....

Show More

A.C. Fundamentals - Resonance in Parallel A.C. Circuits (Parallel Resonance)
Answer : Parallel resonance, also known as anti-resonance, is a phenomenon that occurs in parallel AC circuits when the impedance of the circuit is minimized and the current flowing through the ... of electronics and electrical engineering, as it provides insights into circuit behavior and performance....

Show More

A.C. Fundamentals - Properties of Parallel Resonance
Answer : Parallel resonance is a phenomenon that occurs in electrical circuits when the impedance of the circuit is at its minimum value, resulting in a significant increase in the current ... resonance is crucial for designing and analyzing circuits in various electrical and electronic applications....

Show More

A.C. Fundamentals - Parallel Resonance
Answer : Parallel resonance, also known as anti-resonance, is a phenomenon that occurs in AC (alternating current) circuits containing inductors and capacitors. It is one of the three types ... at resonance. Designing circuits with appropriate damping or loading elements can help mitigate these challenges....

Show More

A.C. Fundamentals - Methods of Solving Parallel A.C. Circuits
Answer : When dealing with parallel AC circuits, there are several methods you can use to solve them. The goal is to find the total impedance, current, and voltage across each component in ... represented as phasors. Make sure to maintain consistency with your phase angles throughout your calculations....

Show More

A.C. Fundamentals - Key Points About Parallel Resonance
Answer : Parallel resonance, also known as anti-resonance, is a phenomenon that occurs in electrical circuits containing inductors, capacitors, and resistors. Here are the key points about parallel ... magnification and excessive current at the resonant frequency if not properly controlled or designed....

Show More

A.C. Fundamentals - Introduction of Parallel A.C. Circuits
Answer : An alternating current (AC) circuit is a circuit in which the voltage and current vary sinusoidally with time. In AC circuits, components like resistors, capacitors, and inductors can be ... the principles of parallel AC circuits is crucial for designing and analyzing complex electrical systems....

Show More

D.C. Motors - Series-parallel control method
Answer : The series-parallel control method is a technique used to control the speed and torque characteristics of a DC motor by changing its armature (rotor) winding configuration. This method is ... DC motors, but it requires careful design and control to ensure optimal performance and reliability....

Show More

A.C. Fundamentals - Transient Response in R-L-C Circuit
Answer : A.C. Fundamentals - Transient Response in R-L-C Circuit In the realm of AC (alternating current) circuits, the behavior of circuits with resistors (R), inductors (L), and ... understanding. Detailed calculations, Laplace transforms, and differential equations are often used for in-depth analysis....

Show More

A.C. Fundamentals - Step Response of R-L-C Circuit
Answer : The step response of an R-L-C circuit refers to how the circuit's output voltage or current responds when a step input voltage is applied to it. An R-L-C circuit is ... Understanding these parameters and the behavior of the circuit helps in designing and analyzing circuits for various applications....

Show More

A.C. Fundamentals - Step Response of R-L-C Circuit
Answer : The step response of an R-L-C circuit refers to how the circuit behaves when a sudden change, or step, is applied to its input voltage or current. The response is characterized by the ... insights into how the circuit responds to sudden changes and how it eventually settles into a stable state....

Show More

A.C. Fundamentals - Step Response of R-L Circuit
Answer : In electrical engineering, the step response of a circuit is the behavior of the circuit when subjected to a sudden change in input, typically from zero to a constant value (step input). ... in the inductor's windings, or mutual inductance if multiple inductors are present in the circuit....

Show More

A.C. Fundamentals - Step Response of R-C Circuit
Answer : The step response of an R-C (resistor-capacitor) circuit refers to the behavior of the circuit when a sudden change, or step, in input voltage is applied. This behavior is especially ... or discharging of the capacitor, and this behavior is characterized by the time constant of the circuit....

Show More

A.C. Fundamentals - Series R-L-C Circuit
Answer : A.C. fundamentals refer to the principles and concepts related to alternating current (A.C.) circuits. A series R-L-C circuit is a type of A.C. circuit that consists of a resistor ( ... , where A.C. circuits are commonly used in applications like filters, tuning circuits, and impedance matching....

Show More

A.C. Fundamentals - Series R-C Circuit
Answer : A series R-C circuit is an electrical circuit that consists of a resistor (R) and a capacitor (C) connected in series to a voltage source (generally an AC voltage source). ... , makes this circuit configuration valuable for applications like filtering high-frequency noise and generating time delays....

Show More

A.C. Fundamentals - R-L-C CIRCUIT
Answer : An RLC circuit, also known as a resonant circuit, is an electrical circuit that consists of three main components: a resistor (R), an inductor (L), and a capacitor (C). These ... circuits can be quite intricate and depends on the interplay between the resistive, inductive, and capacitive elements....

Show More

A.C. Fundamentals - R-L Series A.C. Circuit
Answer : An R-L Series AC circuit is a type of electrical circuit that consists of a resistor (R) and an inductor (L) connected in series to an alternating current (AC) ... These properties have practical applications in various fields, including electronics, power distribution, and signal processing....

Show More

A.C. Fundamentals - R-L Circuit
Answer : An R-L circuit, also known as a resistor-inductor circuit, is an electrical circuit that contains both a resistor (R) and an inductor (L). These components interact to produce specific ... of alternating current (AC) can introduce further complexities due to the changing direction of the current....

Show More

A.C. Fundamentals - R-C Circuit
Answer : An R-C circuit, also known as a resistor-capacitor circuit, is a simple electronic circuit that consists of a resistor (R) and a capacitor (C) connected in series or parallel. This ... the capacitor is charging or discharging and the values of the resistance and capacitance used in the circuit....

Show More

A.C. Fundamentals - Q-Factor of Series Resonant Circuit
Answer : In the context of A.C. (alternating current) circuits, the Q-factor, also known as quality factor, is a measure of how selective a resonant circuit is in responding to a specific ... fundamental concept in the study of A.C. fundamentals and is used extensively in various electronic applications....

Show More

A.C. Fundamentals - Purely Resistive Circuit
Answer : A.C. (alternating current) fundamentals are an important aspect of electrical engineering, particularly in understanding how electrical circuits behave when the current and voltage alternate ... and analyzing various electrical systems, including power distribution networks and electronic devices....

Show More

A.C. Fundamentals - Purely Inductive Circuit
Answer : A.C. (alternating current) fundamentals include the study of various electrical circuits and components that operate with alternating current. A purely inductive circuit is one type of circuit that ... and their study is essential in understanding the behavior of AC circuits in various applications....

Show More

A.C. Fundamentals - Purely Capacitive Circuit
Answer : A.C. (alternating current) fundamentals in a purely capacitive circuit involve understanding how capacitors behave when connected to an AC voltage source. In such circuits, the main component is ... components, such as resistors and inductors, to create more complex circuits with diverse behaviors....

Show More

A.C. Fundamentals - Properties of Resonance of Series R-L-C Circuit
Answer : A series R-L-C circuit is an electrical circuit that consists of a resistor (R), an inductor (L), and a capacitor (C) connected in series. When AC voltage is applied to this circuit, it exhibits certain ... a series R-L-C circuit, the resonant frequency is given by the formula: fₒ = 1 / (2π√(...

Show More

A.C. Fundamentals - Power in R-L series circuit
Answer : In an electrical circuit, power refers to the rate at which energy is consumed or produced. In an AC (alternating current) circuit containing both resistance (R) and inductance ( ... for analyzing the power characteristics and efficiency of AC circuits containing resistive and inductive components....

Show More

A.C. Fundamentals - Power in Pure Resistive Circuit
Answer : In an A.C. (alternating current) circuit, power can be categorized into two types: real power (also known as active power) and reactive power. Let's discuss power in a pure resistive ... like resistance tolerance, wire resistance, and variations in the power factor might lead to some deviations....

Show More

A.C. Fundamentals - Power in Pure Inductive Circuit
Answer : In an AC (alternating current) circuit, power in a pure inductive circuit is an important concept. Let's break down the key points related to power in a pure inductive circuit: ... in applications where reactive power compensation or control is required, such as power factor correction systems....

Show More

A.C. Fundamentals - Power in Pure Capacitive Circuit
Answer : In an AC (alternating current) circuit, power in a pure capacitive circuit is an interesting concept. A pure capacitive circuit consists of only a capacitor and a sinusoidal AC voltage source. ... consumption or dissipation as in the case of real power (which is associated with resistive elements)....

Show More

A.C. Fundamentals - Power in a General Series Circuit
Answer : In AC (alternating current) circuits, power in a general series circuit can be calculated using a combination of the concepts of voltage, current, and impedance. The power in an AC circuit can ... cases, you may need to use phasor diagrams or complex numbers to represent the voltages and currents....

Show More
...